Small Cell will lack the ability to communicate with configuration/fault management portion the EPC
and must rely on you to manually configuring the device.
1) Ensure that you have reserved a static IP inside of the network with IT and installed all the
necessary software for EPC.
2) Point the Small Cell to the established IP of the EPC. Example IP:
192.168.1.222:8080/femsacs/acs
3.1.2 Advanced Setting
Configure Cell Information, REM Settings and ShareRan settings, Navigate to “One Page Setting -
> Advanced Settings. However, if the basic Settings page has been configured properly this section
should be auto configured by the Auto Configuration Sever (ACS).
3.1.2.1 Cell Configuration
1) Cell Identity unique identifier to identify Small Cell. Value cannot be assigned to another
2) small cell in the same network
3) TxPowerMax Maximum power level of the small cell. Sets the LTE max coverage radius.
4) TxPowerMin Minimum power level of the small cell. Sets the minimum LTE coverage
radius.
5) DL_EARFCN_List Specify the downlink Radio Frequency Channel Number for two RF
card. In your use case you are using Band 48. This mean the frequency range is from
3550MHz~3700MHz. It is important to note here that you do not want to set multiple small
Figure 5. Basic Configuration Setting