11.6 Soldering and reflow condition
1) Heating method
Conventional Convection or IR/convection
2) Temperature measurement
Thermocouple d=0.1mm ~ 0.2mm CA (K) or CC (T) at soldering portion or equivalent method.
3) Solder paste composition
Sn/3.0Ag/0.5Cu
4) Allowable reflow soldering times: 2 times, based on the below reflow soldering profile
Suggest reflow soldering one time for better reliability.
5) Temperature profile
Reflow soldering shall be done according to the below temperature profile.
6) Peak temp: 245 degree C
Temperature profile for evaluation of solder heat resistance of a
component (at solder joint)