User Guide
HomeSeer | 10 Commerce Park North, Unit 10 | Bedford, NH 03110 | HomeSeer.com | Doc: HS-MS100-en-v1.0b
HS-MS100+ Z-Wave Moon Sensor
Applicaons
• Use to acvate Z-Wave wall switches or plug-in modules when moon is sensed.
• Use to trigger home automaon events when moon is sensed.
Conguraon
The unit may be powered using the included baery or with a USB power adapter (not included). The unit includes a Z-Wave
network buon (for inclusion/exclusion) and blue LED operaon indicator. A magnec mount allows for very easy installaon.
Z-Wave Network Installaon
Remove the back cover by rotang counter-clockwise and Install 1 CR123A baery (included) inside the unit. Alternately, you
may power the unit with a micro USB connecon. HS-MS100+ may be included into your Z-Wave network as a “secure” device
or as a “non-secure” device. Use the instrucons below to include or exclude HS-MS100+ to/from your Z-Wave network.
Secure Inclusion (recommended if your home controller supports “S0” or “S2” Z-Wave encrypon)
1. Put your home controller into Z-Wave ‘inclusion’ mode.
2. Press and hold the Z-Wave network buon for 5 seconds, then release it. Wait for the inclusion process to nish.
Non-Secure Inclusion
1. Put your home controller into Z-Wave ‘inclusion’ mode.
2. Quickly press and release the Z-Wave network buon once. Wait for the inclusion process to nish.
Exclusion
1. Put your home automaon controller into Z-Wave ‘exclusion’ mode.
2. Quickly triple-press the Z-Wave network buon. Wait for the exclusion process to nish.
Reset (Use this procedure to reset HS-MS100+ to factory sengs when the Z-Wave controller is missing or inoperable).
1. Press and hold the Z-Wave buon for 20 seconds. Release the buon once the LED stops blinking and glows solidly.
Physical Installaon
Install the magnec mount in the locaon of your choice using the supplied double-sck tape or screw. Then aach the main
unit to the mount and point the sensor dome (lens) toward the locaon you wish to monitor.
Moon Sensor Operaon
HS-MS100+ is designed to transmit a Z-Wave command when moon is sensed. It will also transmit another command when
moon has not been sensed for a period of me. This “moon meout” interval is adjustable using a Z-Wave parameter (see
page 2). The default seng of 600 seconds (10 minutes) should yield a good balance of performance and baery life.
Shock Sensor Operaon
The shock sensor is designed to transmit a Z-Wave command when HS-MS100+ has been physically moved. This sensor is espe-
cially helpful in determining whether the unit has been removed from its mount or tampered with.
Baery Sensor Operaon
The baery sensor is designed to report baery level with a Z-Wave command every 43200 seconds (12 hours). If desired,
HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the sengs on the Z-Wave tab of the root device.
OVERVIEW
HS-MS100+ is a compact, easy to install moon sensor. It is designed to control other Z-Wave devices directly or it may be used
with a variety of Z-Wave cered home controllers to launch automaon events or scenes.