HS-MS100+ Z-Wave Moon Sensor
Applicaons
Use to acvate Z-Wave wall switches or plug-in modules when moon is sensed.
Use to trigger home automaon events when moon is sensed.
Conguraon
The unit may be powered using the included baery or with a USB power adapter (not included). The unit includes a Z-Wave
network buon (for inclusion/exclusion) and blue LED operaon indicator. A magnec mount allows for very easy installaon.
Z-Wave Network Installaon
Remove the back cover by rotang counter-clockwise and Install 1 CR123A baery (included) inside the unit. Alternately, you
may power the unit with a micro USB connecon. HS-MS100+ may be included into your Z-Wave network as a securedevice
or as a non-securedevice. Use the instrucons below to include or exclude HS-MS100+ to/from your Z-Wave network.
Secure Inclusion (recommended if your home controller supports S0or S2Z-Wave encrypon)
1. Put your home controller into Z-Wave inclusionmode.
2. Press and hold the Z-Wave network buon for 5 seconds, then release it. Wait for the inclusion process to nish.
Non-Secure Inclusion
1. Put your home controller into Z-Wave inclusionmode.
2. Quickly press and release the Z-Wave network buon once. Wait for the inclusion process to nish.
Exclusion
1. Put your home automaon controller into Z-Wave exclusionmode.
2. Quickly triple-press the Z-Wave network buon. Wait for the exclusion process to nish.
Reset (Use this procedure to reset HS-MS100+ to factory sengs when the Z-Wave controller is missing or inoperable).
1. Press and hold the Z-Wave buon for 20 seconds. Release the buon once the LED stops blinking and glows solidly.
Physical Installaon
Install the magnec mount in the locaon of your choice using the supplied double-sck tape or screw. Then aach the main
unit to the mount and point the sensor dome (lens) toward the locaon you wish to monitor.
Moon Sensor Operaon
HS-MS100+ is designed to transmit a Z-Wave command when moon is sensed. It will also transmit another command when
moon has not been sensed for a period of me. This moon meoutinterval is adjustable using a Z-Wave parameter (see
page 2). The default seng of 600 seconds (10 minutes) should yield a good balance of performance and baery life.
Shock Sensor Operaon
The shock sensor is designed to transmit a Z-Wave command when HS-MS100+ has been physically moved. This sensor is espe-
cially helpful in determining whether the unit has been removed from its mount or tampered with.
Baery Sensor Operaon
The baery sensor is designed to report baery level with a Z-Wave command every 43200 seconds (12 hours). If desired,
HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the sengs on the Z-Wave tab of the root device.
OVERVIEW
HS-MS100+ is a compact, easy to install moon sensor. It is designed to control other Z-Wave devices directly or it may be used
with a variety of Z-Wave cered home controllers to launch automaon events or scenes.