Instruction Manual
Table Of Contents
- 1 Hinweise zur Anleitung
- 2 Gefahrenhinweise
- 3 Funktion und Geräteübersicht
- 4 Allgemeine Systeminformationen
- 5 Montage
- 6 Inbetriebnahme
- 6.1 Installationshinweise
- 6.2 Installation
- 6.3 Verhalten nach Einschalten der Netzspannung
- 6.4 Anlernen
- 6.4.1 Anlernen an den Homematic IP Wandthermostaten
- 6.4.2 Anlernen an die Homematic IP Multi IO Box
- 6.4.3 Einen weiteren Fußbodenheizungscontroller hinzufügen
- 6.4.4 Anlernen an den Homematic IP Access Point
- 7 Konfiguration über den Homematic IP Wandthermostaten
- 8 Manuelle Bedienung
- 9 Geräteverknüpfungen löschen
- 10 Fehlerbehebung
- 11 Wiederherstellung der Werkseinstellungen
- 12 Wartung und Reinigung
- 13 Allgemeine Hinweise zum Funkbetrieb
- 14 Technische Daten
- 1 Information about this manual
- 2 Hazard information
- 3 Function and device overview
- 4 General system information
- 5 Mounting
- 6 Start-up
- 7 Configuration via the Homematic IP Wall Thermostat
- 8 Manual operation
- 9 Delete device connections
- 10 Troubleshooting
- 11 Restore factory settings
- 12 Maintenance and cleaning
- 13 General information about radio operation
- 14 Technical specifications
52
Mounting
5 Mounting
For operation of the floor heating controller with
24 V, a 24 V/50Hz power supply is required. We
recommend you to use the Homematic IP Trans-
former for Floor Heating Controllers – 24 V
(HmIP-FAL24-TR).
When using the floor heating controller
in combination with the Homematic IP
Transformer for floor heating controllers – 24 V
(HmIP-FAL24-TR), it is recommended to install the device
on the supplied DIN rail. For mounting the floor heating
controller and the transformer to a DIN rail, please
proceed as follows:
• Please select a suitable mounting location close
to your heating manifold.
Make sure that no electricity or similar lines run in
the wall at this location!
• Use a pen to mark two bore holes for mounting
the DIN rail on the wall.
• Use an appropriate drill to make the holes as illus-
trated.
• Fasten the screws and plugs supplied to mount
the DIN rail.
• Place the floor heating controller onto the DIN