Instructions

64
Configuration menu
F) in the menu.
Confirm with the menu button.
To confirm, the symbol flashes twice and the device
changes back to automatic mode.
6.2 Manual operation
In manual mode, the temperature is controlled in
accordance with the current temperature set via the
push-buttons (D + F). The temperature remains activated
until the next manual change. To activate the manual
mode, please proceed as follows:
Press and hold down the menu button (E) to
open the configuration menu.
Select “Manu” via the plus and minus buttons (D
+ F) in the menu.
Confirm with the menu button.
To confirm, the symbol flashes twice and the device
changes back to manual mode.
6.3 Oset temperature
As the temperature is measured on the room thermostat,
the temperature distribution can vary throughout a room.
To adjust this, a temperature oset of ±3.5 °C can be set.
If a nominal temperature of e.g. 20 °C is set but the room
presents with only 18 °C, an oset of -2.0 °C needs to
be set. An oset temperature of 0.0° is set in the factory