operation manual

38
Response to power recovery
7 Response to power recovery
After the device has been inserted to a socket or after
power recovery the pluggable dimmer performs a self-
test/restart (approx. 2 seconds). The device LED flashes
orange and green briefly (LED test display). The LED will
flash if an error is detected during this test (see „8.3 Er-
ror codes and flashing sequences“ on page 40). This is
repeated continuously and the device does not perform
its function. If the test is completed without errors, the
pluggable dimmer transmits a wireless telegram contain-
ing its status information.
8 Troubleshooting
8.1 Command not confirmed
If at least one receiver does not confirm a command, the
device LED lights up red at the end of the failed trans-
mission process. The failed transmission may be caused
by radio interference (see „11 General information about
radio operation“ on page 44). This may be caused be
the following:
Receiver cannot be reached,
receiver is unable to execute the command (load
failure, mechanical blockade, etc.) or
receiver is defective.