operation manual
65
Technical specifications
The range of transmission within buildings can 
dier greatly from that available in the open air. 
Besides the transmitting power and the reception 
characteristics of the receiver, environmental 
factors such as humidity in the vicinity have an 
important role to play, as do on-site structural/
screening conditions. 
eQ-3 AG hereby declares that this device complies with 
the essential requirements and other relevant regulations 
of Directive 1999/5/EC. You can find the full declaration 
of conformity at www.eQ-3.de.
11  Technical specifications
Device short description:  HmIP-MIOB
Supply voltage:  230 V/50 Hz
Current consumption:  16 A max.
Standby power consumption:  250 mW
Max. switching capacity:
 Output 1:  3680 W, cos
φ
≥0,95 
(floating)
 Output 2:  1840 W, cos
φ
≥0,95 
(floating)
Cable type and cross section:  rigid and flexible cable, 
0.75 - 2.5 mm²
Kind of load:  ohmic load
Method of operation:  Type 1.B