User manual

26
Hazard information
connected) into account before connecting a
load! All load data relates to ohmic loads. Do not
exceed the capacity specified for the device.
Exceeding this capacity could lead to the de-
struction of the device, fires or electric shocks.
The circuit to the which the device and the load
will be connected has to be secured by a cable
protection switch in accordance with EN60898-1
(tripping characteristic B or C, max. 16 A rated
current, min. 6 kA interrupting rating, energy
limiting class 3). Installation regulations according
to VDE 0100 and HD382 or 60364 have to be
considered. Users must be able to easily access
the cable protection switch. This must be marked
as disconnecting device for the actuator.
Only dimmable 230 V LED lamps may be used.
Not dimmable 230 V LED lamps may destroy the
device and/or the light source.
If the dimming actuator is operated with elec-
tronic transformers, only those which meet the
requirements of DIN EN 61347-1 (VDE 0712-30,
Part 1) along with DIN EN 61047 /VDE 0712-25,
Part 2) may be used.