Instructions

62
Manual operation
Selection of
heating system
P055 0
1
Standard floor
heating
(default)
Low energy floor
heating
For further information regarding the configurati-
on, please refer to the user manual of the Home-
matic IP Wall Thermostat (HmIP-WTH-2).
8 Manual operation
For installation and test purposes, the adaptation runs can
be restarted manually at the individual heating zones or
individual heating zones can be opened or closed.
To start an adapter run manually, proceed as fol-
lows:
Select the required channel using the channel
button (D) (see figure 7).
Press the select button (C) until the open-end
wrench appears at the selected channel in the
display (B) (see figure 7).
If the adaptation run is to be restarted at all hea-
ting zones, you can also use the channel button
to select all channels (keep pressing until all
channels appear in the display) and keep pressing
the select key until the open-end wrench appears
at heating zone „1“ in the display.