Montage- und Bedienungsanleitung Mounting instruction and operating manual Heizkörperthermostat – kompakt S. 2 Radiator Thermostat – compact HmIP-eTRV-C p.
Lieferumfang Anzahl Bezeichnung 1 Homematic IP Heizkörperthermostat – kompakt 1 Homematic IP Demontageschutz – kompakt 3 Adapter Danfoss (RA, RAV und RAVL) 1 Stützring 2 Montagematerial 1 Vierkantschlüssel für das Batteriefach 2 1,5 V LR6/Mignon/AA Batterien 1 Bedienungsanleitung Dokumentation © 2018 eQ-3 AG, Germany Alle Rechte vorbehalten.
1 A C D B 2 E
3 4
G F H 6
7 I 8
Inhaltsverzeichnis 1 2 3 4 5 Hinweise zur Anleitung....................................................8 Gefahrenhinweise.............................................................8 Funktion und Geräteübersicht.....................................10 Allgemeine Systeminformationen............................... 12 Inbetriebnahme............................................................... 12 5.1 5.2 5.3 5.4 6 7 Batterien wechseln.........................................................
Hinweise zur Anleitung 1 Hinweise zur Anleitung Lesen Sie diese Anleitung sorgfältig, bevor Sie Ihr Homematic IP Gerät in Betrieb nehmen. Bewahren Sie die Anleitung zum späteren Nachschlagen auf! Wenn Sie das Gerät anderen Personen zur Nutzung überlassen, übergeben Sie auch diese Anleitung. Benutzte Symbole: Achtung! Hier wird auf eine Gefahr hingewiesen. Hinweis. Dieser Abschnitt enthält zusätzliche wichtige Informationen! 2 Gefahrenhinweise Öffnen Sie das Gerät nicht.
Gefahrenhinweise Betreiben Sie das Gerät nur in trockener sowie staubfreier Umgebung, setzen Sie es keinem Einfluss von Feuchtigkeit, Vibrationen, ständiger Sonneneinstrahlung, Kälte und keinen mechanischen Belastungen aus. Das Gerät ist kein Spielzeug! Erlauben Sie Kindern nicht damit zu spielen. Lassen Sie das Verpackungsmaterial nicht achtlos liegen. Plastikfolien/tüten, Styroporteile etc. können für Kinder zu einem gefährlichen Spielzeug werden.
Funktion und Geräteübersicht Das Gerät ist nur für den Einsatz in Wohnbereichen, Geschäfts- und Gewerbebereichen sowie in Kleinbetrieben bestimmt. Jeder andere Einsatz, als der in dieser Bedienungsanleitung beschriebene, ist nicht bestimmungsgemäß und führt zu Gewährleistungs- und Haftungsausschluss.
Funktion und Geräteübersicht Die zusätzliche Boost-Funktion ermöglicht ein schnelles, kurzzeitiges Aufheizen des Heizkörpers durch vollständige Öffnung des Ventils. Der Heizkörperthermostat passt auf alle gängigen Heizkörperventile und ist einfach zu montieren - ohne Ablassen von Heizungswasser oder Eingriff in das Heizungssystem. Der Sabotagekontakt alarmiert Sie über die Homematic IP App bei Manipulation oder unbefugtem Öffnen des Batteriefachs.
Allgemeine Systeminformationen 4 Allgemeine Systeminformationen Dieses Gerät ist Teil des Homematic IP Smart-HomeSystems und kommuniziert über das Homematic IP Funkprotokoll. Alle Geräte des Systems können komfortabel und individuell per Smartphone über die Homematic IP App konfiguriert werden. Alternativ haben Sie die Möglichkeit, Homematic IP Geräte über die Zentrale CCU2/CCU3 oder in Verbindung mit vielen Partnerlösungen zu betreiben.
Inbetriebnahme Richten Sie zunächst Ihren Homematic IP Access Point über die Homematic IP App ein, um weitere Homematic IP Geräte im System nutzen zu können. Ausführliche Informationen dazu finden Sie in der Bedienungsanleitung des Access Points. Damit der Heizkörperthermostat in Ihr System integriert werden und per Homematic IP App gesteuert werden kann, muss er an den Homematic IP Access Point angelernt werden.
Inbetriebnahme Sie können den Anlernmodus manuell für weitere 3 Minuten starten, indem Sie die Systemtaste (C) kurz drücken (s. Abbildung 4). • • • • • • 14 Das Gerät erscheint automatisch in der Homematic IP App. Zur Bestätigung geben Sie in der App die letzten vier Ziffern der Gerätenummer (SGTIN) ein oder scannen Sie den QR-Code. Die Gerätenummer finden Sie auf dem Aufkleber im Lieferumfang oder direkt am Gerät. Warten Sie, bis der Anlernvorgang abgeschlossen ist.
Inbetriebnahme 5.2 Montage Bitte lesen Sie diesen Abschnitt erst vollständig, bevor Sie mit der Montage beginnen. Die Montage des Homematic IP Heizkörperthermostats ist einfach und erfolgt ohne Ablassen von Heizungswasser oder Eingriff in das Heizungssystem. Spezialwerkzeug oder ein Abschalten der Heizung sind nicht erforderlich.
Inbetriebnahme 5.2.1 Heizkörperthermostat anbringen Bei erkennbaren Schäden am vorhandenen Thermostat, am Ventil oder an den Heizungsrohren wenden Sie sich an einen Fachmann. Demontieren Sie den alten Thermostatkopf von Ihrem Heizkörperventil. Gehen Sie dazu wie folgt vor: • Drehen Sie den Thermostatkopf auf den Maximalwert (G) gegen den Uhrzeigersinn (s. Abbildung 5). Der Thermostatkopf drückt jetzt nicht mehr auf die Ventilspindel und kann so leichter demontiert werden.
Inbetriebnahme • Verschraubung mit Madenschrauben: Lösen Sie die Madenschraube und nehmen Sie den Thermostatkopf ab (H). Nach der Demontage des alten Thermostatkopfes können Sie den Homematic IP Heizkörperthermostat mit der Metallmutter (A) auf das Heizkörperventil aufsetzen (s. Abbildung 6). Bei Bedarf verwenden Sie einen der beiliegenden Adapter für Danfoss Ventile (s. „5.2.3 Adapter für Danfoss“ auf Seite 17) oder den beiliegenden Stützring (s. „5.2.2 Stützring“ auf Seite 17). 5.2.
Inbetriebnahme Achten Sie darauf, sich nicht die Finger zwischen den Adapterhälften einzuklemmen! Die Adapter RA und RAV wurden Zugunsten eines besseren Sitzes mit Vorspannung produziert. Bei Montage verwenden Sie ggf. einen Schraubendreher und biegen diese im Bereich der Schraube leicht auf (s. nachfolgende Abbildungen). Danfoss RA Die Ventilkörper von Danfoss weisen umlaufend längliche Einkerbungen (1) auf, die auch einen besseren Sitz des Adapters nach dem Aufrasten gewährleisten.
Inbetriebnahme 1 2 Danfoss RAV Die Ventilkörper von Danfoss weisen umlaufend längliche Einkerbungen (1) auf, die auch einen besseren Sitz des Adapters nach dem Aufrasten gewährleisten. Achten Sie bei der Montage darauf, dass die Zapfen im Inneren des Adapters (2) eine deckungsgleiche Position zu den Einkerbungen (1) am Ventil haben. Rasten Sie den zum Ventil passenden Adapter vollständig auf. Auf Ventile vom Typ RAV ist vor der Montage die Stößelverlängerung (3) auf den Ventilstift aufzusetzen.
Inbetriebnahme 1 3 2 Danfoss RAVL Die Ventilkörper von Danfoss weisen umlaufend längliche Einkerbungen (1) auf, die auch einen besseren Sitz des Adapters nach dem Aufrasten gewährleisten. Achten Sie bei der Montage darauf, dass die Zapfen im Inneren des Adapters (2) eine deckungsgleiche Position zu den Einkerbungen (1) am Ventil haben. Rasten Sie den zum Ventil passenden Adapter vollständig auf. Der Adapter RAVL muss nicht verschraubt werden.
Inbetriebnahme 1 2 5.3 Adaptierfahrt Nach dem Einlegen der Batterien fährt der Motor den Ventilstift zunächst zurück, um die Montage zu erleichtern. Nachdem der Ventilstift vollständig zurückgefahren wurde (Motor fährt nicht mehr), kann der Heizkörperthermostat montiert werden (s. Abbildung 6). Zur Anpassung an das Ventil muss eine Adaptierfahrt durchgeführt werden.
Inbetriebnahme chen der Ventilstiftendposition gestartet. Der Heizkörperthermostat führt die Adaptierfahrt durch. Nach der Adaptierfahrt ist die Montage beendet und das Gerät kann individuell konfiguriert und gesteuert werden. Wurde die Adaptierfahrt vor der Montage eingeleitet oder konnte nicht vollständig durchgeführt werden, blinkt die Geräte-LED (C) bis zu 10 mal im Abstand von 10 s rot auf. Bei Aktivierung des akustischen Signalgebers ertönt dieser zusätzlich parallel zur LED.
Batterien wechseln J K 6 Batterien wechseln Wird der Blinkcode für leere Batterien über die GeräteLED (C) angezeigt (s. „7.4 Fehlercodes und Blinkfolgen“ auf Seite 27) oder erscheint das Symbol für leere Batterien in der App, tauschen Sie die verbrauchten Batterien gegen zwei neue Batterien des Typs LR6/Mignon/AA aus. Beachten Sie dabei die richtige Polung der Batterien.
Batterien wechseln • • • • • Nehmen Sie den Batteriefachdeckel (B) ab, indem Sie ihn im ersten Schritt nach hinten und im zweiten Schritt nach oben abziehen (s. Abbildung 3). Entnehmen Sie die leeren Batterien. Legen Sie zwei neue 1,5 V LR6/Mignon/AA Batterien polungsrichtig gemäß Markierung in die Batteriefächer ein (s. Abbildung 8). Legen Sie den Batteriefachdeckel wieder ein und verschließen Sie das Batteriefach mit dem Vierkantschlüssel.
Fehlerbehebung 7 Fehlerbehebung 7.1 Schwache Batterien Wenn es der Spannungswert zulässt, ist der Heizkörperthermostat auch bei niedriger Batteriespannung betriebsbereit. Je nach Beanspruchung kann evtl. nach kurzer Erholungszeit der Batterien wieder mehrfach gesendet werden. Bricht beim Senden die Spannung wieder zusammen, wird der Fehlercode am Gerät angezeigt (s. „7.4 Fehlercodes und Blinkfolgen“ auf Seite 27). Tauschen Sie in diesem Fall die leeren Batterien gegen zwei neue aus (s.
Fehlerbehebung 7.3 Duty Cycle Der Duty Cycle beschreibt eine gesetzlich geregelte Begrenzung der Sendezeit von Geräten im 868 MHz-Bereich. Das Ziel dieser Regelung ist es, die Funktion aller im 868 MHz-Bereich arbeitenden Geräte zu gewährleisten. In dem von uns genutzten Frequenzbereich 868 MHz beträgt die maximale Sendezeit eines jeden Geräts 1 % einer Stunde (also 36 Sekunden in einer Stunde). Die Geräte dürfen bei Erreichen des 1 %-Limits nicht mehr senden, bis diese zeitliche Begrenzung vorüber ist.
Fehlerbehebung 7.4 Fehlercodes und Blinkfolgen Blinkcode Bedeutung Lösung Kurzes rotes Blinken im 10 s Abstand Ventilantrieb schwergängig oder Stellbereich zu klein Prüfen Sie, ob der Stößel des Heizungsventils klemmt. Kurzes rotes Blinken im 10 s Abstand Stellbereich zu groß Überprüfen Sie die Befestigung des Heizkörperthermostats Kurzes oranges Blinken Funkübertragung/ Sendeversuch bzw. Konfigurationsdaten werden übertragen Warten Sie, bis die Übertragung beendet ist.
Fehlerbehebung Kurzes oranges Blinken (alle 10 s) Anlernmodus aktiv Geben Sie die letzten vier Ziffern der GeräteSeriennummer zur Bestätigung ein (s. „5.1 Anlernen“ auf Seite 12). Kurzes oranges Leuchten (nach grüner oder roter Empfangsmeldung) Batterien leer Tauschen Sie die Batterien aus (s. „6 Batterien wechseln“ auf Seite 23). 6x langes rotes Blinken Gerät defekt Achten Sie auf die Anzeige in Ihrer App oder wenden Sie sich an Ihren Fachhändler.
Wiederherstellung der Werkseinstellungen 8 Wiederherstellung der Werkseinstellungen Die Werkseinstellungen des Geräts können wiederhergestellt werden. Dabei gehen alle Einstellungen verloren. Um die Werkseinstellungen des Heizkörperthermostats wiederherzustellen, gehen Sie wie folgt vor: • Öffnen Sie das Schloss des Batteriefachs (E) mit dem mitgelieferten Vierkantschlüssel (s. Abbildung 2).
Wartung und Reinigung 9 Wartung und Reinigung Das Gerät ist für Sie bis auf einen eventuell erforderlichen Batteriewechsel wartungsfrei. Überlassen Sie eine Reparatur einer Fachkraft. Reinigen Sie das Gerät mit einem weichen, sauberen, trockenen und fusselfreien Tuch. Verwenden Sie keine lösemittelhaltigen Reinigungsmittel, das Kunststoffgehäuse und die Beschriftung können dadurch angegriffen werden.
Technische Daten Hiermit erklärt die eQ-3 AG, Maiburger Str. 29, 26789 Leer, Deutschland, dass der Funkanlagentyp Homematic IP HmIP-eTRV-C der Richtlinie 2014/53/EU entspricht. Der vollständige Text der EU-Konformitätserklärung ist unter der folgenden Internetadresse verfügbar: www.eq-3.
Technische Daten Maximale Hublage: Minimale Hublage: 14,3 ± 0,3 mm 10,0 ± 0,3 mm Technische Änderungen vorbehalten. Entsorgungshinweis Gerät nicht im Hausmüll entsorgen! Elektronische Geräte sind entsprechend der Richtlinie über Elektro- und Elektronik-Altgeräte über die örtlichen Sammelstellen für Elektronik-Altgeräte zu entsorgen. Konformitätshinweis Das CE-Zeichen ist ein Freiverkehrszeichen, das sich ausschließlich an die Behörden wendet und keine Zusicherung von Eigenschaften beinhaltet.
Technische Daten Package contents Quantity Description 1 Homematic IP Radiator Thermostat – compact 1 Homematic IP Disassembly Protection – compact 3 Adapters Danfoss (RA, RAV and RAVL) 1 Support ring 2 Mounting material 1 Square key 2 1.5 V LR6/mignon/AA batteries 1 User manual Documentation © 2018 eQ-3 AG, Germany All rights reserved. Translation of the original version in German.
Table of contents 1 2 3 4 5 Information about this manual....................................35 Hazard information.........................................................35 Function and device overview.....................................37 General system information.........................................39 Start-up.............................................................................39 5.1 5.2 5.3 5.4 6 7 Replacing batteries........................................................
Information about this manual 1 Information about this manual Please read this manual carefully before beginning operation with your Homematic IP component. Keep the manual so you can refer to it at a later date if you need to. If you hand over the device to other persons for use, please hand over this manual as well. Symbols used: Attention! This indicates a hazard. Please note: This section contains important additional information. 2 Hazard information Do not open the device.
Hazard information The device may only be operated in dry and dustfree environment and must be protected from the effects of moisture, vibrations, solar radiation, cold and mechanical loads. The device is not a toy; do not allow children to play with it. Do not leave packaging material lying around. Plastic films/bags, pieces of polystyrene, etc. can be dangerous in the hands of a child.
Function and device overview Using the device for any purpose other than that described in this operating manual does not fall within the scope of intended use and shall invalidate any warranty or liability. 3 Function and device overview With the Homematic IP Radiator Thermostat you can conveniently regulate the room temperature via the Homematic IP smartphone app according to individually tailored heating phases.
Function and device overview and is easy to mount - without having to drain any water or intervene in the heating system. The tamper contact will alert you in the Homematic IP the app about manipulation or unauthorized opening of the battery compartment. With the supplied disassembly protection, the radiator thermostat is protected against theft and unauthorised disassembly.
General system information 4 General system information This device is part of the Homematic IP smart home system and works with the Homematic IP protocol. All devices of the system can be configured comfortably and individually with the user interface of the Central Control Unit CCU3 or flexibly via the Homematic IP smartphone app in connection with the Homematic IP cloud.
Start-up other Homematic IP devices within your system. For further information, please refer to the operating manual of the Access Point. To integrate the radiator thermostat into your system and to enable control via the Homematic IP app, you must teach-in the device to your Homematic IP Access Point first. To teach-in the radiator thermostat, please proceed as follows: • Open the Homematic IP app on your smartphone. • Select the menu item “Teach-in device”.
Start-up • • • • • • 5.2 Your device will automatically appear in the Homematic IP app. To confirm, please enter the last four digits of the device number (SGTIN) in your app or scan the QR code. Therefore, please see the sticker supplied or attached to the device. Please wait until teach-in is completed. If teaching-in was successful, the LED (C) lights up green. The device is now ready for use. If the LED lights up red, please try again. In the app, give the device a name and allocate it to a room.
Start-up popular manufacturers such as Heimeier, MNG, Junkers, Landis&Gyr (Duodyr), Honeywell-Braukmann, Oventrop, Schlösser, Comap, Valf Sanayii, Mertik Maxitrol, Watts, Wingenroth (Wiroflex), R.B.M, Tiemme, Jaga, Siemens and Idmar. By means of the adapters in the delivery, the device can also be installed on radiator valves of type Danfoss RA, Danfoss RAV and Danfoss RAVL (see „5.2.3 Adapter for Danfoss“ on page 44). 5.2.
Start-up • • fastened this way can be detached by turning the fastener/union nut a little bit counter-clockwise (F). The thermostat head can then be removed (H). Compression fitting: The thermostat dial is held in place by a mounting ring which is held together with a screw. Loosen this screw and remove the thermostat head from the valve (H). Threaded connection with set screw: Loosen the set screw and remove the thermostat head (H).
Start-up 5.2.3 Adapter for Danfoss One of the provided adapters is required to attach to Danfoss valves. The assignment of the suitable adapter to the relevant valve can be found in the following illustrations. Please ensure that you do not trap your fingers between the two halves of the adapter! The RA and RAV adapters have been manufactured with pre-tension in order to provide a better seat.
Start-up Danfoss RA The Danfoss valve bodies have elongated notches (1) around their circumference, which also ensure that the adapter is properly seated when it snaps on. During installation, please ensure that the pins inside the adapter (2) are lined up with the notches (1) on the valve. Ensure that a suitable adapter for the valve is properly clipped on. After clipping onto the valve body, please attach the adapter using the provided screw and nut.
Start-up Danfoss RAV The Danfoss valve bodies have elongated notches (1) around their circumference, which also ensure that the adapter is properly seated when it snaps on. During installation, please ensure that the pins inside the adapter (2) are lined up with the notches (1) on the valve. Ensure that a suitable adapter for the valve is properly clipped on. The lifter extension (3) must be fitted to the valve pin of RAV valves prior to installation.
Start-up Danfoss RAVL The Danfoss valve bodies have elongated notches (1) around their circumference, which also ensure that the adapter is properly seated when it snaps on. During installation, please ensure that the pins inside the adapter (2) are lined up with the notches (1) on the valve. Ensure that a suitable adapter for the valve is properly clipped on. The adapter RAVL does not have to be screwed.
Start-up 5.3 Adaption run Once the batteries have been inserted, the motor reserves the valve pin. After the valve pins has been reversed completely (motor no longer moves), the radiator thermostat can be moved (see figure 6). An adaption run has to be performed in order to adapt the device to the valve. To do this, please proceed as follows: • To start the adaption run, close the battery compartment (E) using the square key (see figure 2+3).
Start-up 5.4 Mounting the disassembly protection If required, you can use the supplied disassembly protection to protect the radiator thermostat against theft and unauthorised disassembly. For the installation, please proceed as follows: • Place the upper (J) and lower (K) shell above the nut or the pre-mounted radiator thermostat and allow the parts to snap into place. After engaging the upper and lower shell, the parts can no longer be separated.
Replacing batteries 6 Replacing batteries If the flashing code for empty batteries is indicated via the device LED (C) (see „7.4 Error codes and flashing sequences“ on page 53) or if the symbol for empty batteries appears in the app, replace the used batteries by two new LR6/mignon/AA batteries. You must observe the correct battery polarity.
Troubleshooting mostat will perform a self-test (approx. 2 seconds). Afterwards, initialisation is carried out. The LED test display will indicate that initialisation is complete by lighting up orange and green. Never recharge standard batteries. Do not throw the batteries into a fire. Do not expose batteries to excessive heat. Do not short-circuit batteries. Doing so will present a risk of explosion.
Troubleshooting 7.2 Command not confirmed If at least one receiver does not confirm a command, the device LED (C) lights up red at the end of the failed transmission process. The failed transmission may be caused by radio interference (see „10 General information about radio operation“ on page 57). The failed transmission may also be caused by the following: • Receiver cannot be reached. • Receiver is unable to execute the command (load failure, mechanical blockade, etc.). • Receiver is defective. 7.
Troubleshooting red flashing of the device LED (C), and may manifest itself in the device temporarily working incorrectly. The device starts working correctly again after a short period (max. 1 hour). 7.4 Error codes and flashing sequences Flashing code Meaning Solution Short red flashing in 10 s intervals Valve drive sluggish or adjustment range too small Please check whether the valve pin is stuck.
Troubleshooting 1x long red lighting Transmission failed or duty cycle limit is reached Please try again (see sec. „7.2 Command not confirmed“ on page 52 or „7.3 Duty cycle“ on page 52). Short orange flashing (every 10 s) Teach-in mode active Please enter the last four numbers of the device serial number to confirm (see „5.1 Teachingin“ on page 39). Short orange lighting (after green or red confirmation) Batteries empty Replace the batteries (see „6 Replacing batteries“ on page 50).
Restore factory settings Long and short orange flashing (alternating) 8 Update of device software (OTAU) Wait until the update is completed. Restore factory settings The factory settings of the device can be restored. If you do this, you will lose all your settings. To restore the factory settings of the radiator thermostat, please proceed as follows: • Open the lock of the battery compartment (E) using the supplied four Allen head wrench (see figure 2).
Maintenance and cleaning • Release the system button to finish the procedure. The device will perform a restart. 9 Maintenance and cleaning The device does not require you to carry out any maintenance other than replacing the battery when necessary. Enlist the help of an expert to carry out any repairs. Clean the device using a soft, lint-free cloth that is clean and dry. Do not use any detergents containing solvents, as they could corrode the plastic housing and label.
General information about radio operation 10 General information about radio operation Radio transmission is performed on a non-exclusive transmission path, which means that there is a possibility of interference occurring. Interference can also be caused by switching operations, electrical motors or defective electrical devices. The range of transmission within buildings can differ greatly from that available in the open air.
Technical specifications 11 Technical specifications Device short name: Supply voltage: Current consumption: Battery life: Degree of protection: Degree of pollution: Ambient temperature: Dimensions (W x H x D): Weight: Radio frequency band: Maximum radiated power: Receiver category: Typ. open area RF range: Duty cycle: Method of operation: Connection: Controlling torque: Valve travel: Maximum travel position: Minimum travel position: Subject to technical changes. 58 HmIP-eTRV-C 2x 1.
Technical specifications Instructions for disposal Do not dispose of the device with regular domestic waste! Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive. Information about conformity The CE sign is a free trading sign addressed exclusively to the authorities and does not include any warranty of any properties. For technical support, please contact your retailer.