operation manual
48
49
Start-up
Start-up
Step 1 Switch o the fuse of the power circuit.
Step 2 If necessary, pull the rocker o the frame
of the relevant switch. Then pull the
frame o the switch together with the
clamping/retaining piece. The clamping/
retaining piece can be transparent, grey
or black depending on the manufacturer,
and holds the frame onto the switch.
To make removal easier, a flat, pointed
object such as a slotted screwdriver can
be used.
Step 3 Release the wiring and remove the exist-
ing switch if necessary.
Step 4 On-o circuit: Connect the conduc-
tor to the lamp/luminaire at connecting
terminal 2 (D).
Two-way circuit: Connect the two cor-
responding supply cables to the two-way
switch at connecting terminals 1 (C) and
2 (D) .
Intermediate switch circuit: Connect the
two corresponding supply cables to the
intermediate switch circuit at connecting
terminals 1 (C) and 2 (D) .
Step 5 Connect the phase conductor to con-
necting terminal L (B) .
Step 6 Connect the neutral conductor to con-
necting terminal N (E) .
Step 7 Connect the neutral conductor of the
lamp / luminaire to the neutral conductor
of the house installation.
Step 8 Secure the switch actuator and meter to
the flush-mounted box using the pro-
vided screws. Please note that the system
button (A) of the actuator must be at the
top left during installation.
Step 9 Fit the adapter to the rocker (see figure 5).
Step 10 Now secure the rocker with the adapter
in the frame on the actuator.
Position the adapter so that both latching
lugs fit into the existing elongated holes
(see figure 6).
Step 11 Switch the fuse of the power circuit back
on again.
Step 12
Now the switch actuator and meter can
be taught-in to the Homematic IP Access
Point (see „6.3 Teaching-in“ on page 50).