operation manual

35
Hazard information
The circuit to the which the device will be
connected has to be secured by a cable
protection switch in accordance with EN60898-1
(tripping characteristic B or C, max. 16 A rated
current, min. 6 kA interrupting rating, energy
limiting class 3). Installation regulations according
to VDE 0100 and HD382 or 60364 have to be
considered. Users must be able to easily access
the cable protection switch. This must be marked
as disconnecting device for the actuator.
Before the actuator is connected, remove the
fuse from the fuse box
.
Except for configuration, the device may only be
operated with an associated switch cover.
The device may only be operated within residen-
tial buildings.
Using the device for any purpose other than that
described in this operating manual does not fall
within the scope of intended use and shall invali-
date any warranty or liability.