User manual

47
Start-up
Step 3 Release the wiring and remove the existing
switch if necessary.
Step 4 Connect the switched phase conductors
for connecting terminals 1 and 2 to the
motor as follows (see fig. 2):
Connecting terminal 1
(C): “Down”
Connecting terminal 2 (D): “Up”
Step 5 Connect the phase conductor to connect-
ing terminal L (B) .
Step 6 Connect the neutral conductor to con-
necting terminal N (E) .
Step 7 Connect the neutral conductor of the mo-
tor to the neutral conductor of the house
installation.
Step 8 Secure the blind actuator to the flush-
mounted box using the provided screws.
Please note that the system button (A) of
the actuator must be at the top left during
installation.
Step 9 Fit the adapter to the rocker (see figure 3).
Step 10 Now secure the rocker with the adapter in
the frame on the actuator.
Position the adapter so that both latching
lugs fit into the existing elongated holes
(see figure 4).