User manual

46
Start-up
Please observe the hazard information in section
“2 Hazard information” on page 34 during in
-
stallation.
Permitted cable cross sections for connecting to the
blind actuator are:
rigid cable [mm
2
] flexible cable with/without
ferrule [mm
2
]
0.75 – 1.50 0.75 – 1.50
6.2 Installation
You can use the blind actuator in a blind, shutter or awning
circuit (see fig. 2). To install the blind actuator, please pro
-
ceed as follows:
Step 1 Switch o the fuse of the power circuit (see
“6.1 Installation instructions” on page 44).
Step 2 If necessary, pull the rocker o the frame
of the relevant switch. Then pull the frame
o the switch together with the clamping/
retaining piece. The clamping/retaining
piece can be transparent, grey or black
depending on the manufacturer, and holds
the frame onto the switch.
To make removal easier, a flat, pointed
object such as a slotted screwdriver can
be used.