Instructions

37
Hazard information
In order for the device to be connected to the
supply voltage and the consumer load work
needs to be carried out on live voltage-carrying
parts. Before connecting the device, remove the
fuse from the fuse box.
The device may only be operated with the associ-
ated cover.
The circuit to which the device will be connected
has to be secured by a cable protection switch in
accordance with EN60898-1 (tripping characteris-
tic B or C, max. 16 A rated current, min. 6 kA inter-
rupting rating, energy limiting class 3). Installation
regulations according to VDE 0100 and HD382 or
60364 have to be considered. Users must be able to
easily access the cable protection switch. This must
be marked as disconnecting device for the actuator.
The load connected to the relay output requires
sucient insulation.
The device has not been designed to support
safety disconnection. The load is not isolated
from the mains.
No SELV/PELV circuits may be connected to the
relay outputs.