Instructions

46
Start-up
sary, personal safety equipment;
Evaluation of measuring results;
Selection of electrical installation material for safeguard-
ing shut-o conditions;
IP protection types;
Installation of electrical installation material;
Type of supply network (TN system, IT system, TT sys-
tem) and the resulting connecting conditions (classical
zero balancing, protective earthing, required additional
measures etc.).
Please observe the hazard information in section
“2 Hazard information” on page 38 during in-
stallation.
Please note the insulation stripping length of the
conductor to be connected, indicated on the
device.
Permitted cable cross sections for connecting to the
blind actuator are:
rigid cable [mm
2
]
flexible cable without ferrule [mm
2
]
0.75 – 2.50 0.75 – 2.50
5.2 Mounting and installation
Please read this entire section before starting to
install the device.
To install the blind actuator on a DIN rail within a
distribution board, please proceed as follows: