User manual
38
Mounting
In doing so, ensure that the positions of the cover drain hole and
the sensor support line up (the housing drain hole should be fac-
ing outwards).
Step 4:
• Remove the pipes of the stainless steel mast (I) from the pack-
aging.
• Join the pipes together. The previously assembled weather sen-
sor is fixed to the end of the pipe that is marked with a sticker.
• Place the fully assembled sensor within the potential transmis-
sion radius (up to 400 m typically in the open air, with damping
caused by building walls taken into account). Choose a free posi-
tion in which it is possible for rain to fall directly into the rain sen-
sor, but where there is no risk of inaccurate wind measurements
caused by nearby buildings, trees, etc.
It may be placed in a sunny location since the temperature sen-
sor is located in a shaded, ventilated area of the housing.