User manual
55
Start-up
6.2 Installation
To install the floor heating actuator, please proceed as
follows:
• Open the cover (D). Therefore, release the catch
under the slot for opening (C) by pushing it with
a screwdriver. Remove the cover by pulling it up-
wards (see fig. 5).
• Connect the transformer to the connecting ter-
minals (F) of the floor heating actuator.
Press the terminal down using an appropriate
screw driver to open the connecting terminal.
Thread the corresponding cable. Release the ter-
minal to close it and to fix the cable (see fig. 6).
• Plug in the connecting cable of the valve actu-
ators in your heating circuits to the connecting
terminals (G-H). Connect a heating pump using
connecting terminal (G).
• Make sure that all connecting cables are fixed
properly to the cable bushings before closing the
cover.
• Close the cover again. Therefore, push the latch-
es of the cover into the openings provided and
press it down.
• Plug the mains plug of the transformer into a
socket.