User manual

50
Delete device connections
Press the select button until the LED (B) flashes green three times.
The channel will be switched on or o for 15 minutes. Afterwards, normal
operation will be continued for the heating zone.
8.2 Activating/deactivating the pump control
If you want to use connection terminal (F) for controlling a heating pump,
the heating zone can be switched to pump control directly via the device.
To do this, proceed as follows:
Press the select button (B) until the LED of channel 1 starts flash-
ing green (see fig. 7).
If the LED of channel 1 starts flashing slowly, the pump control is
activated. If the LED of channel 1 starts flashing quickly, the pump
control is deactivated.
If you do not want to change any parameters, you can exit the
menu by pressing the select button (B) briefly.
To switch the parameter from activated to deactivated or from
deactivated to activated, press and hold down the select button
(B) for at least 4 seconds.
9 Delete device connections
To delete the device connections between the floor heating actuator and
the wall thermostat, please proceed as follows:
Select the channel of the floor heating actuator to which the wall
thermostat is connected using the select button (B) (see fig. 7).