User manual

48
Configuration via the Homematic IP Wall Thermostat
Channel parameter ChAn:
Parameter Index
Value
Meaning
Switch on delay for
pump
(only for channel 1)
P006 128
129
130
...
147
148
0 minutes
1 minute
2 minutes (default)
...
19 minutes
20 minutes
Duration of pump
protection function
(only for channel 1)
P007 128
129
...
137
138
0 minutes
1 minute (default)
...
9 minutes
10 minutes
Switch o delay for
pump
(only for channel 1)
P008 128
129
130
...
147
148
0 minutes
1 minute
2 minutes (default)
...
19 minutes
20 minutes
Minimum floor
temperature in
connection with a floor
temperature sensor
P045 10
11
...
38
...
59
60
5.0 °C
5.5 °C
...
19.0 °C (default)
...
29.5°C
30.0°C
Humidity limit P050 40
80
168
188
208
40 %: humidity limit
deactivated
80 %: humidity limit
deactivated
40 %: humidity limit activated
60 %: humidity limit activated
(default)
80 %: humidity limit activated