User manual

42
Start-up
5.2.3 Support ring
The valves from dierent manufacturers may have tol-
erance fluctuations that make the radiator thermostat
more loosely seated on the valve. In this case, the pro-
vided support ring (R) should be placed into the flange
before mounting the radiator thermostat (see figure 5).
5.3 Adaption run
Once the batteries have been inserted, the motor
reserves. Meanwhile, “ ” and the activity
symbol ( ) are displayed.
After the radiator thermostat has been mounted suc-
cessfully, an adaption run ( ) has to be per-
formed in order to adapt the device to the valve. To do
this, proceed as follows:
• As soon as “ ” is displayed, press the con-
trol wheel/boost button (E) to start the adaption run.
Now the actuator performs an adaption run. “
and
the activity symbol ( ) are displayed. During this time,
no operation is possible. After the adapting run has been
successful, the display returns back to normal.
If the adapter run has been initiated prior to mount-
ing or if an error message (F1, F2, F3) is displayed,
press the control wheel/boost button (E) and the
motor reverses to the “ ” position.