Technical Specifications
Page 7 of 8 IN079 Rev A
RN104 PRODUCT SPECIFICATIONS
The following chart shows fan performance for the RN104 Radon Fan:
Typical CFM Vs Static Suction "WC
0" 0.5" 1.0" 1.5"
RN104 112 95 70 40
Maximum Recommended Operating Pressure*
RN104 1.8" W.C. (Sea Level Operation)**
*Reduce by 10% for High Temperature Operation
**Reduce by 4% per 1000 feet of altitude
Power Consumption @ 120 VAC
RN104 45 - 66 watts
RN104 Inlet/Outlet: 4.5" OD (4.0" PVC Sched 40 size compatible)
RN104 Inlet/Outlet: 5.875" OD
Mounting: Mount on the duct pipe or with optional mounting bracket.
Recommended ducting: 3" or 4" Schedule 20/40 PVC Pipe
Storage temperature range: 32 - 100 degrees F.
Normal operating temperature range: -20 - 120 degrees F.
Maximum inlet air temperature: 80 degrees F.
Size: 9.5H" x 8.5" Dia.
Weight: 6 lbs.
Continuous Duty
Thermally Protected
Class B Insulation
3000 RPM
Residential Use Only
Rated for Indoor or Outdoor Use