Installation Guide

2
www.homewerksww.com
PRODUCT SPECIFICATIONS
SPECIFICATIONS SPECIFICATIONS
Max. Flow Rate: 1.2 GPM (4.54 LPM) at 60 PSI Ceramic cartridges
ASME A112.18.1/CSA B125
Manufactured to include no more than 0.25% weighted average lead content
on wetted surfaces
NSF 61-9
Polished chrome, brushed nickel or oil rubbed bronze nish
ASSEMBLY INSTRUCTIONS
1. Turn off water at the supply valve
under the sink or at the main water
supply, disconnect the supply line,
and remove old faucet.
Clean and dry surface area where
new faucet will be mounted.
1
5. Remove the bottom gasket (1) and
nut (2) from the top gasket (3) and
pop-up body (4).
3
2
1
4
5
2.
Optional Flange Installation:
Before installation, ensure that the
ange (1) is placed on the bottom
of the new faucet assembly (2). Place
the faucet assembly (2) through the
mounting hole in the sink. Secure the
faucet assembly (2) with the plastic
washer (3), metal washer (4) and nut
(5). Hand tighten the nut (5) onto the
faucet assembly (2) shank. Lock the
nut (5) into position by tightening the
screws (6) with a Phillips screwdriver.
1
2
4
6
5
3
2
6. Insert the pop-up body (1) into
the sink. Ensure that the top
gasket (2) rests securely between
the top of the sink and the top of
the pop-up body (1).
1
2
6
3.
Optional Deck Plate
Installation:
Before installation, remove the ange.
Align the hole in the gasket (1) and
deck plate (2) with the mounting
hole in the sink. Place the faucet
assembly (3) through the deck plate
(2) and mounting hole in the sink.
Secure the faucet assembly (3) with
the plastic washer (4), metal washer
(5) and nut (6). Hand tighten the
nut (6) onto the faucet assembly (3)
shank. Lock the nut (6) into position
by tightening the screws (7) with a
Phillips screwdriver.
NOTE: If the sink is uneven, use
silicone under the gasket (1).
4
6
5
1
2
3
7
3
7. From underneath the sink, screw
the bottom gasket (1) and nut (2)
onto the pop-up body (3) by
twisting clockwise until secure.
1
2
3
7
4.
Connecting Water Lines:
Use 1/2 in. I.P.S. faucet connections
(2) (not included), or use supply line
coupling nuts (3) (not included) with a
3/8 in. O.D. ball-nose riser (1). Before
tightening the faucet connector to the
water supply, apply a second wrench
to the supply tube tting. This will
prevent the supply tube from moving
or twisting when tightening the faucet
connector. Do not overtighten.
NOTE: The hot side inlet tube is
indicated by a label.
3
2
1
4
8. IMPORTANT: After installation
is complete, remove the aerator
from the faucet with a coin (1) to
ush the water lines. Turn on the
water supply and allow both hot
and cold water to run for at least
one minute each. This ushes away
any debris that could cause damage
to internal parts. While the water is
running, check for leaks. Turn off the
water and replace the aerator.
1
8