Parts List
10
HomewerksWW.com
EXISTING CONSTRUCTION INSTALLATION INSTRUCTIONS (continued)
9. Remove the wiring cover. Pull the house wires through the 
wiring cover hole. Using the attached quick connectors, connect 
120v house wiring to the fan as shown in the wiring diagram 
on page 5. 12-18 AWG is the smallest conductor that should 
be used for branch circuit wiring. 
Carefully push the connected wires back into the wiring box 
housing. Reattach the wiring box cover.
CAUTION: If the house electrical wires do not match the 
colors from the fan wiring diagram on page 5, you must 
determine what each house wire represents before 
connecting. You may need to consult an electrical 
contractor to determine safely.
Wire
cover
Wire
cover
House
wire
Product
wire
Quick
connect
9
10.  Connect a 4 in. circular duct (not included) and vent to the 
outside. Secure it with duct tape (not included) or a clamp 
(not included) to make the connection secure and airtight. 
Finish ceiling work. Ceiling hole should be aligned with edge  
of the fan housing (A).
10
A
11. Plug the connector attached to the grille (B) into the  
connector on the fan housing (A).
11
A
B
Connector
12.  Attach the grille (B) by pinching the mounting springs 
and inserting into the narrow rectangular slots in the 
fan housing (A). 
Turn on the power source. If you hear any abnormal sound  
or vibration, please refer to the Troubleshooting Guide on 
page 12.
12
A
B
Mounting
spring