Instructions / Assembly

12
www.homewerksww.com
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan seems louder than
it should
CFM too great
Be sure the CFM rating on the fan matches the
size of your room.
Damper not working properly or damaged
Check damper to ensure it is opening and closing
properly. If the damper has become damaged,
please call Customer Service.
Bend in duct too close to fan discharge
Be sure you do not have any sharp bends in duct
closer than 18 in. to the fan discharge.
Fan discharge reduced to t smaller duct
Use recommended size ducting to reduce fan
noise.
Fan body not securely attached
Be sure the fan is securely attached to your ceiling
joists.
The fan is not
clearing the room
Insufcient intake airow within room
Be sure a door or window is slightly ajar or opened
to allow airow. The fan is not able to draw air out of
the room without enough airow to draw from.
Insufcient CFM
Be sure the CFM rating on the fan matches the
requirements for your room size.
NOTE: Using a tissue is not an accurate method
for determining if the fan is operating properly. If the
fan clears steam from the room
within approximately 15 minutes of completing your
shower, then the fan is operating properly.
Device will not pair Another device is already paired.
Make sure BLUETOOTH
®
signal is turned off on
other devices.
4. Replace the BLUETOOTH
®
speaker and grille.
Turn on power source.
CARE AND MAINTENANCE