Use and Care Manual

Customer Service Hotline 1-877-693-PURE
Page 4
Home Master® Reverse Osmosis System—Owners Manual
adapter as outlined later.
Installing The Home Master® Reverse
Osmosis System
1. Mount RO Faucet*
1. Use existing hole, or drill 1/2” hole in sink top.
See page 3.
2. Slide small rubber washer onto faucet shank,
then metal escutcheon plate.
3. Slide rubber washer onto faucet shank.
4. Insert shank through hole in sink.
5. Slide locating washer, followed by locking
washer onto shank under sink.
6. Thread either lock nut or wingnut hand
fastener onto shank, position faucet and
tighten.
7. Wrap threaded shank with Teflon tape 1-2
times. DO NOT tape to end. Leave final
thread exposed for easier fitment.
8. Hand tighten the 3/8” RO faucet adapter.
Avoid cross-threading faucet adapter,
by first rotating the adapter counter-
clockwise until it seats, then finger-
tighten.
Note: RO faucet is non-air gap. If an air gap faucet
is required for your installation, one can be
provided to you at no charge upon request with
alternate drain saddle and tubing. Call customer
service 1-877-693-7873.
2. Install EZ adapter on cold water line -
Always wear protective eyewear. Locate the cold
water angle-stop (the main water lines under the
sink – one hot water, one cold water), and turn
clock-wise to shut off the water. Locate 3/8”
fitting, typically found on the line out of the angle-
stop or where the existing line connects to the
kitchen faucet. Disconnect the 3/8” fitting on
either the angle-stop or the kitchen faucet. Use
Teflon tape on the EZ adapter and the angle-stop
male threads, and make sure o-rings are properly
seated. Fit the EZ adapter and tighten. Make sure
EZ adapter ball valve is in the closed position then check for water pressure & leaks on ball valve.
Close EZ adapter valve, by turning the handle perpendicular to the tube opening as shown below.
Open angle-stop valve by rotating angle-stop counter-clockwise. Have a bowl or cup nearby to
catch water. Dry all parts, check for leaks, and snugness.
Faucet Adapter EZ Adapter on angle-stop Reserve Tank Shut-off Valve