Dynamix HP-51M User Manual EN-V1.00 Dynamix HP - 51M HomePNA3.1 Coax MDU Master Bridge User’s Guide Version 1.0 Jul.
S TATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Dynamix HP-51M User Manual EN-V1.
Allowed Source _______________________________________________________________________ 20 Telnet/Http/Snmp Setup _______________________________________________________________ 21 System Log _____________________________________________________________________________ 22 System Time ____________________________________________________________________________ 22 Static MAC _____________________________________________________________________________ 23 Reboot System___________________________________________
Dynamix HP-51M User Manual EN-V1.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 1 I NTRODUCTION This chapter describes the features of your HomePNA3.1 over Coax to Ethernet Master (Management) Bridge -HP-51M. Refer to “HomePNA3.1 over Coax” as HCNA from this point. Features ♦ One HCNA Port for Driving HomePNA3.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 2 I NSTALLATION This chapter describes the installation procedure for your bridge. Packing List Your package should come with the equipment listed below, ♦ ♦ ♦ ♦ One Main Unit (HCNA to Ethernet Master Bridge) HP-51M One DC 5V Power Adaptor One F-Type Coaxial Cable (RG-59U) One RJ-45 Ethernet Cable (CAT-5) Rear Panel Figure 1: Rear Panel of HP-51M Connectors 1. DC5V: Connect to the power adapter plug. 2.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Connecting the Cables To establish a new coax networking system by HP-51M, reroute the CATV/Antenna signal source over coax toward HP-51M ‘TV/Antenna’ port and connect HP-51M ‘HCNA’ port to the original coax entrance to building. HP-51M works as a Combiner for TV and HCNA signal. In each Dwelling Unit, use the HCNA EP to extract the TV signal and Ethernet packets.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide You can also use other Combiner or Mixer-Splitter with HP-51M to build the same system, see the following Figure 3 for different cabling, Satellite/CATV VHF/UHF Mixer Combiner EP HP-51M Splitter M/C Optical Fiber ISP Figure 3: Different Cabling of HP-51M NOTE: After power up HP-51M, the led ‘SynMode’ will always be glowing, and led ‘Link/Act’ will light up for at least one EP is detected on the HCNA network.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 3 C ONFIGURATION This chapter describes the configuration procedure for your bridge. Configuration Methods To access and configure your bridge, choose one of the following methods: ♦ Use Web Browser ♦ Use Telnet Program ♦ Use SNMP Manager or MIB Browser Use Web Browser Web browser is the easiest tool to configure the bridge. The factory default IP address of HP-51M is ‘192.168.1.1’ and the default subnet mask is ‘255.255.255.0’.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide System Setup (TCP/IP Properties) The main window contains the left sub-window for the items to be configured, and the right sub-window displays the contents for the selected item. Click your mouse on the item in the left window will pop out the corresponding item-window in the right side. Click on the ‘Apply’ button (or ‘OK’ button in some screens) will submit your new setting into the bridge and will take effect immediately.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide manage other connected Slave EPs. The HCNA MAC exists only in HCNA (coax) domain, and is unaware for any EP end-user. System manager use system IP address and Ethernet MAC address to access HP-51M. Each HP-51M device should be stamped with both Ethernet MAC and HCNA MAC for identification. Figure 4: EP Management Architecture Firmware/Driver Files HP-51M flash ROM is capable of storing the following files: 1. System bootcode (OS bootloader) 2.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Each row represents for one EP, here we have one Master (Local) HCNA device (on the top) and 7 extra Slave EP devices shown on the window. The first two are EPs based on 3010, follows three Smart EPs based on 3110 (or called Configurable EPs), and the last two EPs that are powered off. Smart EP Denote an EP whose Ethernet properties are configurable.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Config : configure Master’s/Smart EP’s both HomePNA and Ethernet properties or EP’s sole HomePNA properties. Del : Delete the off-line EP’s profile, to save the EP properties profile space of HP-51M. Test : run the built-in diagnostic functions. Refer “Diagnosis” for more details. Click on each device’s ‘HPNA’ button can open the window to configure its HomePNA properties.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide HCNA driver with the new values (replace the running working values with the new setting ones) before any connected EP can access the network controlled by HP-51M. Privacy Mode Usage Example For example, first activate the ‘Privacy Mode’ by apply the ‘ON’ setting and change the ‘Privacy Key’ to ‘0x1234’. HP-51M will request to upgrade the Master’s HCNA driver, and all allowable EP’s HCNA driver.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Here we have one banned EP shown in red background after upgrade, Then power on the 2 extra off-line EPs, they will also be banned since their ‘Privacy Mode/Key’ (as default ‘OFF’/‘0x0’) doesn’t match with the Master’s (now key is ‘ON’/‘0x1234’ ).
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide EPs are classified by the shown background color, green for allowed EP, red for banned EP. Privacy Mode/Key Summary EP can’t communicate with each other regardless of the settings of ‘Privacy Mode’ and ‘Privacy Key’. EP could access the coax network controlled by HP-51M only if EP has the right ‘Privacy Mode’ and ‘Privacy Key’.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Yellow: For Master, it has inconsistent ‘Privacy Mode/Key’ settings. You may upgrade the Master’s driver to synchronize its working values. (to replace the running working values with the setting ones). Red: For banned EP, either ‘Privacy Mode/Key’ in EP is not matched or the ‘Host Limit’ value in EP is 0. HP51M will refuse to serve this EP.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Service and Speed/Duplex Change ‘Service’ to enable or disable the port. This setting open or close the related Ethernet switch port in EP. Default setting in field ‘Speed/Duplex’ is ‘Auto’ states for auto-negotiation. Bandwidth Control Consider port HCNA as the network backbone and refer the following diagram to set up bandwidth control parameters in EP’s Ethernet switch (Regards as Hardware bandwidth control, works for both upstream and downstream).
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide QoS Setup Total 4 prioritized queues are provided for Ethernet packets, denoted as Queue0 (lowest priority), Queue1, Queue2 and Queue3 (highest priority). You may assign the different packet dropping ratio and service weight for different queue. Refer Chapter “ADVANCED FEATURES” for more HP-51M QoS mechanism details.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide The following diagram denotes the path for tagged packets according to the above settings, Second example, enable Tag VLAN in EP only, and keep Master Tag VLAN disabled as default, accompanied the following packet path diagram.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Status and Statistics Show port LAN1/LAN2/HCNA Ethernet switch port link status and port statistics. Reset to Default Works for EP only, to reset all Ethernet settings/configurations of EP to factory default, including ‘Port Setup’, ‘QoS Setup’, ‘IGMP v2 Snooping Setup’, and ‘Tag VLAN Setup’. Delete the Obsolete EP Profile For the off-line EP only, the light in Link field in gray, click on the ‘Del’ button will delete the EP profile.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Device Noise in Master and EP ‘Noise Test’ measures each individual device HCNA interface noise level (noise floor). For example, use a Master alone with 75Ω terminator, here shows the Master noise frequency spectrum diagram after test, Connect only one EP to Master, with 30dB attenuator add-on. Here’s the ‘Noise Test’ result of the connected EP, Physical Connection between Master and EP Connect only one EP to Master, with 30dB attenuator add-on.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide This diagnosis runs the downstream test from HP-51M toward EP. Also the result of ‘Rx Diagnose’ of the same gears, This diagnosis runs the upstream test from EP to HP-51M. The shown factors ‘SNR’, ‘Lost Pkts’, ‘PE’ and ‘RX Power’ are obtained during communication diagnosis between the tested EP device and Master device. SNR: Normally between 38dB~42dB. Lost Pkts: Denominator is the total number of transmitted packets in one test run.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Administrator For each account, 3 level of privilege is provided: Superuser, Read, and ReadWrite. The unchangeable username ‘admin’ always have the ‘Superuser’ rights. To add user account, you need to have the ‘Superuser’ privilege, Allowed Source Factory default filter set for the ‘IP address’ is ‘0.0.0.0’ and the ‘Subnet Mask’ is ‘0.0.0.0’ in ‘Allowed Source’ setting.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide For each programmed filter set, you can further specify if the protocol Telnet/Http/Snmp/Ping is enabled or not. Be careful not to block your current IP from accessing HP-51M remotely; else you have to press the Reset Button locally and restart from factory default settings.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Specify that if the built-in Telnet server, Web server, and Snmp agent is enabled or not and assign the port number for the service. System Log By designating the Syslog server IP on HP-51M, HP-51M will emit Unix-like Syslog events toward each server.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide For example, To access your listed SNTP server by its domain name instead of IP address, the ‘DNS Server’ and ‘Default Gateway’ in ‘System Setup’ window need to be set up correctly. In order for HP-51M to access the SNTP server by its domain name. Static MAC It may be necessary to bind and secure the server/gateway MAC addresses to port LAN1/LAN2 of HP-51M for security. Static MAC is using to prevent MAC-spoofing-attack in Ethernet network.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Activate Firmware To do the real upgrade for ‘Bootcode’ or ‘System Firmware’, make the previous uploaded image functional. Refer the following “Example to Upload then Activate System Firmware and HCNA Driver” for more details. Backup/Restore Configuration Use to backup current configuration into a file with filename extension ‘.shc’. Or to restore the HP-51M configuration form the previous saved file.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide In the example, the onboard Master (denoted ‘Local’) device driver version is ’2.7.5-2’. The two 3010 EP’s device driver version is ‘2.7.5-2’, and the five 3110 Smart EP’s driver version is also ‘2.7.5-2’. It is possible that these three type HCNA devices could be equipped with different driver versions and cooperate inside one working coax network.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Click ‘Browse’ button to locate where the new system firmware resides at your PC, then click ‘Start’ button to upload the file (HP51M_Sysfw_V3.06.bin) onto your HP-51M, Uploading in progress, Another count-down counter to verify the integrity of uploaded file, Verifying is ok, click ‘Continue’ button.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide You may activate the new system firmware right away, or wait for the proper scheduled time in order not to disturb current operation. Check the New System Firmware in ‘Upload Area’ After the successful uploading, you may check the uploaded ‘System Firmware’ does exist in ‘Upload Area’. By opening the ‘System Firmware’ window in the ‘Activate Firmware’ function item, here shows the new system firmware version ’3.06’.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide If you don’t upload ‘System Firmware’ first, the ‘Upload Area’ is blank, Activate the New System Firmware Click ‘Activate’ button in the ‘System Firmware’ window will do the real upgrade and replace the old ‘System Firmware’ (OS), A progress counter for upgrade HP-51M system firmware, HP-51M will reboot after upgrade has completed, 28
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide New system firmware version ’3.06’ shown on the ‘Information’ window, HCNA Driver Upload the New Master/EP HCNA Driver Follow the similar procedures as to upload new system firmware, start from the ‘Upload Firmware’ window… Click ‘Start’ button to upload the file (HP51M_Driver_V2.7.5-3.bin) onto your HP-51M, And complete, New HCNA driver version ’2.7.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Also shown on ‘EP Management’ window (‘Upload Area’), Upgrade the New HCNA Driver Designate the targeted Master/EPs for driver upgrade from version ‘2.7.5-2’ to ‘2.7.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Click ‘Upgrade’ button to proceed, Then ‘Upgrade’ button again to confirm, Upgrade EP one by one, will keep the Master (Local) for the last, 31
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Master/EP runs the New HCNA Driver The ‘EP Management’ window that queries the properties from each HCNA device, Indicate the new driver version ‘2.7.5-3’ is working. System Firmware and HCNA Driver Version after Upgrade As shown on the ‘Information’ window for summary.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 33
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Use Telnet Any popular Telnet client could use to configure the bridge remotely. For example, run Windows built-in Telnet to configure the bridge, Input any command with ‘-h’ argument will show you the usage, as ‘dconfig –h’ will explain the function and usage of command ‘dconfig’. For security consideration, please disable the ‘Telnet Server’ if the bridge is not to be configured via Telnet.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Note that Telnet connection will be terminated automatically if the telnet client doesn’t input any command for 5 minutes; i.e. the console idle timer is 10 minutes (600 Sec). Command Sets for Telnet Console The following table lists all commands for Telnet console. The third column ‘Description’ explains what happen when you run the ‘Commands’ in the first column and also explains the versatile options of the second column ‘Arguments’.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide dir [-s ] dns exit quit ep ephpnareboot Show detail file information resides in flash ROM. Include ‘Working Area’ and ‘Upload Area’, refer Figure 4.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide hpnareboot ipconfig logserver master passwd ping reboot rmep service showep Reset Master HCNA device’ Display or set up system IP network, include IP address , subnet mask , and default gateway .
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide [-s [-c ] [-p ] snmptrapserver [-a ] [-m ] ] [-l ] [-u ] [-s ] snmptrapsetup [-d ] sntp stat swconfig swigmp swqos swqosrate swqostc swsmac Display or set up SNMP trap server(s) configuration.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide swtagvlan tftp time upep [-c ] addresses can be setup, refer Static MAC : max 8 entries : bind the current MAC entry to LAN1 or LAN2 port, i.e. enable this MAC entry as static MAC :disable this MAC entry, neither bind to LAN1 nor LAN2 : remove the current MAC entry, invalid this MAC entry to default 00-00-00-00-00-00 [-c ] Display or set up the LAN1/LAN2/HCNA Tag VLAN.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Use SNMP The SNMP Agent resides in HP-51M will handle requests from remote SNMP Manager. The HP-51M SNMP agent supports standard SNMP community-based operations (SNMP V1/V2c) as ‘SET’, ‘GET’ and ‘TRAP’. You need to specify the correct Read-Only Community Name into bridge before any SNMP ‘GET’ operation can work. Also set up the Read/Write Community Name for SNMP ‘SET’ operation. ‘SET’ operation can modify the setting within HP-51M.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide 4 A DVANCED F EATURES This chapter describes the advanced features offered by your bridge. QoS Quality of Service is enforced by assigning each incoming packet with a predefined priority value. Packet with higher priority should be processed as soon as possible (fast in, fast out). In shortage of buffers, some low priority packets should be discarded to smooth the high priority traffic flow.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide A S PECI FICATIONS NETWORK INTERFACE HomePNA3.1 over Coax(HCNA) Compliant IEEE 802.3u 100Mbps Fast Ethernet IEEE 802.3 10Mbps Ethernet IEEE 802.
DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide Max Attenuation to Endpoint: 50dB (-176dBm/Hz Noise Floor) CONNECTORS Ethernet LAN Port: 2 Ports, RJ45 Jack HCNA Port: 1 F-Type Port to HCNA Coax Network TV/Antenna Port: 1 F-Type Port to TV Set or from CATV/Antenna LED INDICATOR Power Ethernet LAN Link/Activity per Port HCNA Link/Activity HCNA SyncMode HCNA Endpoint Diagnosis TERMINAL DEVICES(ENDPOINT) Cooperate with HCNA Ethernet Bridge Endpoint (as HP-51S) Support