Use and Care Manual

Page 12
Range Hood Operations
In addition to the remote control feature, this range hood is also equipped with a heat sensor that will self-calibrate
-
Adjusting Heat Sensitive Auto Speed (HSAS) Function:
• Press Auto Function
LCD Panel when Auto Mode is On.
Auto Function button to enter the temperature setting
mode. Press Increase or Decrease button to adjust the comparison temperature value between the internal and
external heat sensors from 7°F to 20°F. The temperature setting mode will exit automatically after 5 seconds of
inactivity.
automatically when the internal temperature is 4 times above the external temperature. Then it will adjust the
speed level (between speed levels F4 to F1) automatically according to the detected temperature between the
sensors (4 times to 1 time). The speed level can also be manually overwritten by press the Increase or Decrease
Activating Normal Blower Function:
Increase or Decrease button to start the blower. Press Increase button
to increase blower speed (F1 to F4) as indicated in LCD panel. The Increase button cycles blower settings from
• While the range hood is on and the blower is running, press Decrease button to decrease blower speed
(F4 to F1) as indicated in LCD panel. The Decrease button cycle blower settings from high speed (F4), to medium
Remote Control
Sensor
Delay
Light
LCD Panel
Decrease
Increase
Auto Function