Venting Requirements
Vent system must terminate to the out-• 
side (roof or side wall), unless using a 
recirculating kit.
Do not terminate the vent system in an • 
attic or other enclosed area.
Do not use 4” (10.2 cm) laundry-type • 
wall caps.
Use metal/aluminum vent only. Rigid • 
metal/aluminum vent is recommended.
Do not use plastic vent.• 
Always keep the duct clean to ensure • 
proper airow.
Calculate the following gures before • 
installation:
Distance from the oor to the ceil-1. 
ing.
Distance between the oor to the 2. 
countertop/stove (recommend 24in 
to 30in).
Distance between the countertop/3. 
stove to the range hood.
Height of hood and duct cover.4. 
For the most efcient and quiet 
operation:
It is recommended that the range hood • 
be vented vertically through the roof 
through 6” (15 cm) round metal/ alu-
minum vent work.
The size of the vent should be uniform.• 
Use no more than three 90° elbows.• 
Make sure there is a minimum of 24” • 
(61 cm) of straight vent between the 
elbows if more than one elbow is used.
Do Not install two elbows together.• 
The length of vent system and number • 
of elbows should be kept to a mini-
mum to provide efcient performance.
The vent system must have a damper. • 
If roof or wall cap has a damper, Do 
Not use damper supplied with the 
range hood.
Use duct tape to seal all joints in the • 
vent system.
Use caulking to seal exterior wall or • 
roof opening around the cap.
Height & Clearance
Cabinet
Range hood
Venting Pipe
36” base
Min:
24” 
Max: 30”