- HAI OmniPro II Owner's Manual
Table Of Contents
- INTRODUCTION
- OVERALL DESCRIPTION
- SECURITY SYSTEM OPERATION
- Disarming the Security System and Silencing Alarms
- Arming the Security System
- Using Shortcut Keys
- Quick Arm
- Bypassing Zones
- Restoring Zones
- What To Do When You Come Home
- What Happens When the Alarm is Activated
- Emergency Keys
- Duress Code Entered or Duress Alarm Activated
- Alarm Reset
- Alarm Cancel
- Trouble Indications
- Codes
- Duress Code
- Panic Switches
- Area Arming
- GOTO Area
- Testing Your System
- CONTROL
- Control Commands
- About UPB
- HAI Lighting Control (HLC) Format
- About CentraLite
- About Lutron RadioRA
- About ALC
- About X-10
- House Codes
- Unit Numbers
- Scrolling Through Names
- Controlling Units
- Timed Commands
- Status of a Unit
- Internal Flags
- Controlling Outputs
- All On / Off
- Leviton Scene Control
- Buttons
- Temperature Control
- HAI RC-Series Thermostats
- Programmable Energy Saver Modules (PESMs)
- Temperature Alarms
- Humidity
- Status
- Event Log
- Messages
- TELEPHONE CONTROL
- Telephone Interface
- In-House Phones
- Remote Phones
- Phone Access Denied - Remote Lockout
- Alternate Method
- Main Menu
- 1 - Control
- 2 - Security
- 3 - Button
- 4 - All
- 5 - Temperature
- 6 - Status
- 7 - Events
- 8 - Message
- 9 - Good-Bye
- Panic Button over the Phone (# # # # # #)
- Emergency Dial-Out
- Digital Dialer
- Voice Dialer
- PC Access
- Built-In Ethernet Port
- Controller IP Address, Port Number, and Encryption Key
- OmniPro II Ethernet Connections
- Connecting to Network via PC Access
- Dynamic DNS
- SETUP
- UNDERWRITER'S LABORATORIES REQUIREMENTS
- FEDERAL COMMUNICATION COMMISSION NOTICE:
- CANADIAN INDUSTRY CANADA NOTICE
- APPENDIX A - DIAL OUT PLANNER
- APPENDIX B - TEXT DESCRIPTION CHARACTER CODES
- APPENDIX C - VOICE DESCRIPTION CODES
The next series of displays shows the current analog reading for each security zone input. The displays show the readings for
zones 1-176.
1=147 2=148 3=147
4=146 5=146 6=147
THROUGH
175=148 176=147
↑
Normal readings for zones are between 137 - 157 when secure. If Zones 1-4 are configured as Fire or Gas zone, normal readings
are between 26 - 43 when secure. Each reading should be changing only by two or three counts from its average steady reading.
When a door or window is opened, the reading will go up to a value that represents that zone is open.
This feature can be used to monitor the quality of the zone wiring and contacts. If the numbers begin to deviate from their
original values when the system was new, wiring problems that will eventually lead to trouble or false alarms may be developing.
You may wish to record the Status Test values for future reference.
5 = TEMP (TEMPERATURE)
The Temperature Status menu allows you to view and scroll through the status of each Thermostat, PESM, and Temperature
Sensor. To enter the Temperature menu, from the Status menu, press the 5 key on the console keypad. The system will display:
TSTAT 1 TEMP:80
↓
HEAT:60 COOL:82
You may enter a unit number to start displaying the status with that unit, or simply press the down arrow key to scroll through the
list of temperature zones. The status display is as shown under Temperature Control, except that now the arrow keys may be used
to continue scrolling.
TSTAT 1
MODE: AUTO FAN: AUTO
At this point, you may press the ' # ' key to control the temperature zone as specified under Temperature Control.
6= ENERGY (ENERGY COST)
The Energy Cost Status menu allows you to view the current energy rate in use.
ENERGY COST: MID
The Energy Cost will display Lo, Mid, Hi or Crit (for critical) energy rates.