POWERING ON YOUR SPA
After lling the spa through the lter assembly to the correct level and removing the water hose, replace the lter, the lter basket assembly and lter cover. Turn
the GFCI on. Every time the GFCI is powered on, your spa controls run diagnostic self checks. During diagnostic testing, it is normal for a series of messages to
display on your topside controls. When diagnostic self checks are completed, the spa will start in priming mode.
Priming Mode
Each time you ll your spa, some air may be trapped in the plumbing lines. Priming mode safely removes the air. To prevent overheating and serious
damage, the heater is disabled during priming mode. Your spa starts up in priming mode every time the GFCI is powered “ON” and ends automatically
after approximately 6 minutes. When Priming Mode is complete, the primary pump will run on low speed until the pre-set water temperature is reached.
Run Pumps to Purge the Air
When this message is displayed on your topside controls, push the “Pump ” button once to start the pump on low speed. Press the “Pump” button a
second time to switch to high speed. After conrming water is coming from all jets and the pump is not surging, press the “Pump ” button to turn the
pump o.
Within 2 minutes of pressing each pump button, water should be owing from the jets in every seat without surging. If none of the jets in a seat work or if water
surges, turn the pump o. When the water in the spa is completely still, repeat the process to initiate a second pump priming session. If the pumps do not prime
within 2 minutes on your second attempt, turn the GFCI o. Make sure the slice valves are locked in the up position, that the diverter valves are centered for even
distribution of the water, that any jet without ow is rotated to the open position and remove any debris in the lter basket and on suction drain covers in the foot
well. Power the GFCI on and when the Priming Mode message is displayed on the topside controls, repeat the process to run each pump on HIGH SPEED. If the
pumps don’t prime on the third attempt, call 844-894-6659 for assistance.
Do not turn on any pump that will not prime. A pump that fails to prime should not be left on for more than 2 minutes under any circumstance. The heater will
engage when priming mode is complete. If a pump is not properly primed when the heater engages, the spa may overheat causing serious damage.
Pre-Programmed Factory Settings
The spa will start in Standard Operating Mode.
The temperature is pre-programmed to 100° F.
The minimum programmable temperature is 80º F, the maximum is 104º F
The Filtration cycle is pre-programmed to run for twice each day for two hours.
While the water is heating, the temperature is measured approximately every two minutes. After the spa has been running for 2 minutes, the current water
temperature will be displayed on the topside controls. When the water temperature reaches the pre-programmed temperature setting, the pump will automatically
turn o. To display the current pre-programmed temperature setting, press the “cool” button once. The current water temperature will ash on the display.
When the display is ashing, the spa controls are in programming mode. To prevent accidentally changing pre-programmed settings, after you press a button, you
should wait 5 seconds before pressing a dierent button.
Turning the Jets On and Off
Press the “Pump” button once to turn the pump on low speed. Press the “Pump” button a second time to turn the pump on high speed. Pressing the
“Pump” button a third time will turn it o. The pump will shut down automatically after 20 minutes. To turn the pump back on, simply press the “Pump”
button. If your spa is equipped with an Ozonator, Ozone will be generated automatically whenever the pump is running on low speed.
To ensure your safety and for optimal performance, your spa controls will automatically perform maintenance functions and run diagnostic testing. The pump will start
automatically on low speed to circulate the water every thirty minutes to run a system check. During heating, ltration and diagnostic testing the pump runs on low
speed. When the pump starts automatically to preform these actions, pressing the pump button will not turn the pump o.
Turning the Lights On and Off
Press the “Light” button once to turn the lights on. The colored light will rotate. Press the “Light” button to turn the light o. To display only one color,
press the “Light” button repeatedly turning the lights on and o. When the color your desire turns on do not turn the light o. Press the button when you
are ready to turn the light o. The lights will turn o automatically after 2 hours. Press the “Light” button to turn the lights back on. If your spa is equipped
with optional perimeter lighting, the perimeter lighting feature works in tandem with the main light.
Operating the Audio Components
Music from your Mp3 player will play through the built in audio components when the audio system is powered on and the device is plugged into the
audio jack. Both the on/o switch and audio jack are located inside the Mp3 Cargo Bay. The Mp3 Cargo Bay is built into the spa cabinet on the same
side as the topside controls. To power on the audio system, open the sliding door on the Mp3 Cargo Bay and press the rocker switch on. Use your
Mp3 player to select music and to control the volume. If the model you purchased is equipped with Bluetooth capability, open the Bluetooth settings on
your Mp3 player and connect it to the spa to stream your music wirelessly. Enter “0000” if a pairing code is required.
For your safety and to protect your device, your Mp3 player should always be stored in the Mp3 Cargo Bay. When you remove your Mp3 player from the
Cargo Bay, always push the rocker switch down to turn the speakers o. Leaving the audio components on causes overheating that will permanently damage
the audio components. Damage to the audio components that occurs because the components were not turned o is not covered under the warranty.
Changing the Programmed Temperature Setting
To change the pre-programmed temperature setting, press the “cool” button once. The programmed water temperature will ash on the display. While
the programmed water temperature is still ashing press the “cool” button again to reduce the programmed temperature setting or the “warm” button to
increase it. After 3 seconds, the display will stop ashing and the current water temperature will again be displayed.
The controls are in programming mode when the display is ashing. If the display is not ashing when the temperature is adjusted, the changes will not be saved.
Freeze Protection
If the water temperature falls to 44º F, the spa will automatically turn on and will run for 4 minutes after the water temperature reaches 46º F to
prevent freezing. If your spa is in Sleep Mode when the ambient temperature is 40º F or lower, the water temperature will likely operate in Freeze
Protection Mode for extended periods if not continuously.