Use and Care Manual
For technical support and assistance, call 844-894-6659
22
POWERING ON YOUR SPA
After lling the spa through the lter assembly to the correct level and removing the water hose, replace the lter, the lter basket
assembly and lter cover. Turn the GFCI on. Every time the GFCI is powered on, your spa controls run diagnostic self checks.
During diagnostic testing, it is normal for a series of messages to display on your topside controls. When diagnostic self checks are
completed, the spa will start in priming mode.
Priming Mode
Each time you ll your spa, some air may be trapped in the plumbing lines. Priming mode safely removes the air. To
prevent overheating and serious damage, the heater is disabled during priming mode. Your spa starts up in priming mode
every time the GFCI is powered “ON” and ends automatically after approximately 6 minutes. When Priming Mode is
complete, the primary pump will run on low speed until the pre-set water temperature is reached.
Run Pumps to Purge the Air
When this message is displayed on your topside controls, push the “Pump ” button once to start the pump on low speed.
Press the “Pump” button a second time to switch to high speed. After conrming water is coming from all jets and the pump
is not surging, press the “Pump ” button to turn the pump o.
Within 2 minutes of pressing each pump button, water should be owing from the jets in every seat without surging. If none of the jets
in a seat work or if water surges, turn the pump o. When the water in the spa is completely still, repeat the process to initiate a second
pump priming session. If the pumps do not prime within 2 minutes on your second attempt, turn the GFCI o. Make sure the slice
valves are locked in the up position, that the diverter valves are centered for even distribution of the water, that any jet without ow is
rotated to the open position and remove any debris in the lter basket and on suction drain covers in the foot well. Power the GFCI on
and when the Priming Mode message is displayed on the topside controls, repeat the process to run each pump on HIGH SPEED. If
the pumps don’t prime on the third attempt, call 844-894-6659 for assistance.
Do not turn on any pump that will not prime. A pump that fails to prime should not be left on for more than 2 minutes under any
circumstance. The heater will engage when priming mode is complete. If a pump is not properly primed when the heater engages, the
spa may overheat causing serious damage.
Pr