STORAGE BETWEEN USES
• Turn the control knob off.
• Disconnect the LP source.
• Store the re pit in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail,
snow, dust and debris).
• If desired, cover the re pit to protect exterior surfaces and to help prevent build-up in air passages.
Note: Wait until the re pit is cool before covering.
STORAGE DURING PERIODS OF EXTENDED INACTIVITY OR WHEN TRANSPORTING
• Turn the control knob off.
• Disconnect LP source and move to a secure, well-ventilated location outdoor.
• Store the re pit in an area sheltered from direct contact with inclement weather (such as rain, sleet, hall,
snow, dust and debris).
• If desired, cover the re pit to protect exterior surfaces and to help prevent build-up in air passages.
• Never leave the LP cylinder exposed to direct sunlight or excessive heat.
Note: Wait until re pit is cool before covering.
SERVICE
Only a qualied service person should repair gas passages and associated components.
Caution: Always allow the re pit to cool before attempting service.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Burner won’t light
Propane cylinder is empty Replace propane cylinder
Blockage in orice Clear blockage
Control knob is not in “ON” position Turn control knob to “ON”
Burner ame is low
Gas pressure is low Turn cylinder valve off and re-ll the cylinder
Outdoor temperature is less than 40°F
and tank is less than 1/4 % full
Use a full cylinder
Control knob fully on Check burner and orices for blockage
Carbon build-up Dirt or lm on burner Clean burner
Thick black smoke Blockage in burner Remove blockage and clean burner inside and outside
Troubleshooting