Safety Data Sheets (SDS)
4096 AEROSOL WALL TEXTURE WATER BASED - ORANGE PEEL - COLOR
CHANGING
Product name
9
Product code
Date of issue
Version
00384862
24 July 2020
Section 8. Exposure controls/personal protection
Limestone
OSHA PEL (United States, 5/2018).
TWA: 5 mg/m³ 8 hours. Form: Respirable
fraction
TWA: 15 mg/m³ 8 hours. Form: Total dust
dimethyl ether
None.
Talc , not containing asbestiform fibres
ACGIH TLV (United States, 3/2019).
TWA: 2 mg/m³ 8 hours. Form: Respirable
OSHA PEL Z3 (United States).
TWA: 2 mg/m³
Isopropyl alcohol
ACGIH TLV (United States, 3/2019).
STEL: 400 ppm 15 minutes.
TWA: 200 ppm 8 hours.
OSHA PEL (United States, 5/2018).
TWA: 980 mg/m³ 8 hours.
TWA: 400 ppm 8 hours.
crystalline silica, respirable powder (<10 microns)
ACGIH TLV (United States, 3/2019).
TWA: 0.025 mg/m³ 8 hours. Form:
Respirable
OSHA PEL Z3 (United States, 6/2016).
TWA: 10 mg/m³ / (%SiO2+2) 8 hours. Form:
Respirable
TWA: 250 mppcf / (%SiO2+5) 8 hours. Form:
Respirable
OSHA PEL (United States, 5/2018).
TWA: 50 µg/m³ 8 hours. Form: Respirable
dust
Ingredient name
Exposure limits
Appropriate engineering
controls
:
Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapor
or mist, use process enclosures, local exhaust ventilation or other engineering controls
to keep worker exposure to airborne contaminants below any recommended or statutory
limits. The engineering controls also need to keep gas, vapor or dust concentrations
below any lower explosive limits. Use explosion-proof ventilation equipment.
Recommended monitoring
procedures
:
If this product contains ingredients with exposure limits, personal, workplace
atmosphere or biological monitoring may be required to determine the effectiveness of
the ventilation or other control measures and/or the necessity to use respiratory
protective equipment. Reference should be made to appropriate monitoring standards.
Reference to national guidance documents for methods for the determination of
hazardous substances will also be required.
Key to abbreviations
A
Acceptable Maximum Peak
=
ACGIH
=
American Conference of Governmental Industrial Hygienists.
C
=
Ceiling Limit
Potential skin absorption
S
SR
=
Respiratory sensitization
=
Skin sensitization
SS
TD
=
Total dust
Consult local authorities for acceptable exposure limits.
=
Threshold Limit Value
TLV
TWA
=
Time Weighted Average
Fume
=
F
IPEL
=
Internal Permissible Exposure Limit
=
Occupational Safety and Health Administration.
OSHA
R
=
Respirable
OSHA 29 CFR 1910.1200 Subpart Z - Toxic and Hazardous Substances
=
Z
STEL
=
=
Short term Exposure limit values
United States
Page: 6/14