Technical Specifications

PART 1 GENERAL
1.1 Section Includes
A. Sound-deadening acoustical flooring
systems.
1.3 References
A. ASTM E 84– test method for surface
burning characteristics of building
materials.
B. ASTM D 1037–test methods of
evaluating properties of wood-base
fiber and particle panel materials
1.4 Submittals
A. Submit under provisions of section
01300.
B.
Product data: manufacturers catalog
data, detail sheets, and specifications.
C.Quality assurance/control submittals:
1. Manufacturer
’s installation
instructions.
1.5 Quality Assurance
A. Manufacturers qualifications:
1. Minimum 10 years experience in
producing sound-deadening boards
of the type specified herein.
1.6 Delivery
, Storage, and Handling
A. Deliver materials in manufacturers
original packages.
B. Inspect the materials upon delivery to
assure that specified products have
been received.
C.Report damaged material immediately
to the delivering carrier and note
such damage on the carrier
s freight
bill of lading.
D.
Store materials in a dry place, indoors,
or on raised platform protected from
weather damage.
P
AR
T 2 PRODUCTS
2.1 Manufacturers
A.
Acceptable manufacturer: Homasote
Company
, P
.O. Box 7240, W
est
Trenton, NJ 08628-0240; ASD.
T
el: (800) 257-9491,
Fax: (609) 883-3497,
Internet address:
http://www
.homasote.com;
for local rep contact: Sweet’
s Buyline
1-800-892-1165 (#0878).
B.
Requests for substitutions will be
considered in accordance with
provisions of section 01600.
C.
Substitutions: not permitted.
D.
Provide all sound-deadening boards
from a single manufacturer.
2.2 Materials
A.
Sound-deadening boards: Homasote
440 SoundBarrier®; physical proper-
ties as follows:
1.
Thickness: 1/2 inch (13mm), 5/8
inch (16mm), 3/4 inch (19mm).
2. Density: 26-28 pcf (416-448
kg/cubic m).
3. Tensile strength: 450-700 psi
(3,100-4, 830 kPa).
4.
Hardness (Janka Ball): 230 lbs.
(104 kg).
5. Water absorption by volume;
ASTM D 1037:
a. 2 hour immersion: 5 percent
maximum.
b.
24 hour immersion: 15 percent
maximum.
6. Expansion, 50 to 90 percent rela-
tive humidity: 0.25 percent.
7. R-value: 1/2 inch 1.2 (0.021),
5/8 inch 1.33, 3/4 inch 1.4.
8. Flame spread: Class III (or C).
9. Noise reduction coefficient: 0.20.
2.3
Accessories
A. Adhesive: APA AFG-01 approved.
B. Angular thread nails: length as
required to penetrate a minimum of
3/4 inch (19mm) into sub-floor; 1inch
(25mm) into framing.
C. Screws:
1. Coarse thread drywall type wood
screw, length as required to
penetrate 3/4 inch (19mm) into
sub-floor.
PART 3 EXECUTION
3.1
Examination
A.
Examine substrates upon which work
will be installed.
B.
V
erify framing member spacing
complies with manufacturer
s
requirements depending on substrates
and installation methods.
C.
V
erify environmental conditions are,
and will continue to be, maintained in
accordance with manufacturer
s
recommendations.
D. Coordinate with responsible entity to
perform corrective work on unsatis
-
factory substrates or conditions.
E. Starting work by installer is
acceptance of substrates and
environmental conditions.
3.2 Preparation
A.
Follow manufacturers instructions by
separating and allowing Homasote
440 SoundBarrier® to be exposed to
environmental temperature and
humidity conditions for not less than
24 hours before start of installation.
B.
440 SoundBarrier® panels must be
installed in a clean, dry condition.
DO NOT INSTALL WET PANELS.
It is essential to make every ef
fort
to prevent water from ponding on
installed panels. 440 SoundBarrier®
panels must be thoroughly dry prior
to closing in the structure.
3.3
Installation
A. Follow manufacturers instructions for
cutting and installation of Homasote
440 SoundBarrier
®.
B. Over wood sub-floors: walls and
ceilings use 440 SoundBarrier®:
1.
Using all approved APA sub-floor
adhesive meeting APA-AFG-01
specifications, apply a 3/8 inch
bead of adhesive. Holding back 3/4
inch from panel edges and in an “X”
pattern within the field as shown in
the “nailing and adhesive pattern.”
2.
Allow 3/16 inch (4.7mm) space at
panel joints, and 3/8 inch (9.5mm)
space along walls and partitions.
3.
Use proper length ring shank nails
or screws to penetrate 3/4 inch
(19mm) into sub-floor: 1 inch
(25mm) into framing.
4. If omitting adhesive, panels must be
nailed or screwed 6 inch o.c. along
panel edges and 10 inch o.c.
throughout the field of the board.
5.
Hold back nails or screws 3/8 inch
(9.5mm) from panel edges.
3.4
Adjusting and Cleaning
A.
Replace panels that cannot be
repaired.
440 SoundBarrier
®
SPECIFICA
TIONS
8
932 Lower Ferry Road, W
est
T
renton, New Jersey 08628
800-257-9491 609-883-3300 Fax: 609-883-3497 609-530-1584
Sales Extension 1500 sales@homasote.com Technical Support: Extension 1332
www.homasote.com techhelp@homasote.com