User Manual
9. The load cell assembly is designed to rock in place. The cell should be seated in the upper and lower
receiver plates.
10. Wiring the load cell are all wired into the junction box located under the access plate in the center of
one side of the platform.
Corner numbering
3 4
J-box
2 1
+ EXC = GREEN
-EXC = BLACK
+SIG = WHITE
-SIG = RED
SHIELD = BARE OR YELLOW