4. If dead spaces are to be used these need to be placed as needed. They are designed for either stone
fill for temporary use or to be filled with concrete for more permanent use. If filled with concrete a
rebar pattern of 12” square of ½” rebar is recommended. If you plan on moving them after concrete
is poured a heavy visqueen should be placed below them so they do not adhere to the surface. They
also have lifting rings on the four corners if you would like to move them in the future.
5. After all modules and dead spaces are in place the scales can be ramped up to with stone or optional
ramps can be installed.