Owners manual
4
11.0 HYDRAMAT INSTALLATION EXAMPLE – POLYPROPYLENE FUEL CELL
NOTE: We recommend buying a new tank or having your tank professionally cleaned before installation of the
HydraMat.
1. Install the corner magnets as instructed in kit 16-203 to the HydraMat (Figures 1a & 1b).
Figure 1a Figure 1b
2. Torque the 3/8” barbed hose adapter into the HydraMat outlet (20-24 FT. LBS.) Cut the in-tank rubber hose (Kit# 26-
148 includes hose, bulkhead, nut, stat-o-seals, and clamps or Kit# 26-161 2 ft. 3/8” hose only kit) to the desired length
and clamp in place. (Figure 2)
Figure 2
3. Cover the edge of the tank opening with electrical tape or duct tape. (Figure 3).
4. Form/fold the HydraMat and insert through the tank opening (Figure 4). Position it on the tank floor and then locate
the external magnets opposite the magnets secured to the HydraMat (Figure 5).
Figure 3 Figure 4