2.1.3 When the transmitter is being stored or otherwise not used, the protective
top cover should be kept closed to prevent actuation from accidental
button depression.
2.1.4 It is advisable to check the battery level periodically by removing the side-
plate, setting the channel number switch to position 0, and holding
down the FIRE button. While the button is pressed, the battery level will
be displayed on the BATTERY LEVEL INDICATOR as described in
section 1.2. No radio transmission occurs if the channel number switch is
in position 0.
WARNING - Be sure no receivers are armed or connected to live
devices while performing this test to prevent the possibility of
accidental actuation in the event of erroneous channel number
selection (non- zero selection).
Battery check should typically be performed once per month during
moderate usage or once per week during heavy usage. Heavy usage is
considered to be several actuations per day, and moderate usage is once
per day or fewer.
Be sure to return the channel number switch to its proper position after
completion of the battery test.
2.2 MAINTENANCE.
Since there are no calibration or tuning adjustments in the transmitter, the only
maintenance required is periodic replacement of the 3 volt battery. This should
be done at least once per year, or at the next opportunity if the “Battery Level”
light fails to flash when enabled.