Data Sheet
Title
Drawing.
No.
UXM-30LXH-EWA Specification
C-42-04104
10/10
9. Heater function
This sensor is provided with an internal heater for preventing dew condensation. It is possible to enable the
heater function to “on” or “off” using the dedicated application program. Heater function is “off” by default.
When heater function is “on” the heater operates when the temperature inside the sensor is 0°C or below. When
the temperature inside the sensor exceeds 10°C, operation of the heater is automatically stopped.
Note) When using the heater function, it is recommended to use the sensor at the voltage of 24 V.
(If it is used at 12 V, the heating may not be sufficient due to lack of power to the heater.)
10.Setting of Ethernet
10.1 Default value
Default value of IP: 192.168.0.10
Port No.: 10940
10.2 Initialization of IP
Detach the packing for protection at the bottom of the product, and press the IP initialization
switch for 2 sec or more.
The sensor restarts after blinking the green and orange LEDs, release the switch.
The packing for protection shall be replaced after initialization without fail.
For details on changing the IP address, refer to the manual attached to the IP changer
application.
Bottom face
of UXM
IP initialization switch
Ventilation window
Power cable
Connector for Ethernet