Product Specifications
Title
Drawing
No
UTM-30LX/LN Specification
C-42-3615
6/6
7.2 Detection Output (UTM-30LN)
When the signal is set for detection output .The signal switches OFF when obstacle exist inside the area.
(Output signal is ON when obstacle does not exist.
Area can be set using 3~7 co-ordinate points.
Maximum of the output delay is 128 times (3.2 sec)
Example
8. Malfunction Output:
1. Laser malfunction : When laser does not radiate or exceeds safety class 1.
2. Motor malfunction : When rotation speed is differ from the default value (> 25 m/s).
Synchronous/Warning signal will be turned OFF when these malfunctions are detected. Error details can be
obtain via communication.
9. Cautions
Heat is generated as the sensor runs at a very high speed. The heat generated is concentrated at
the bottom of the sensor. Please mount heatsinks or any appropriate component to release the
generated heat. An aluminum plate (200 x 200 x 2) is recommended as the heatsinks.
Error could happen when 2 or more identical sensor is mounted at the same detection plane.
This is because the sensor could not identify the origin of the received laser pulses. When this error
occur, it will cause 1 -2 step difference, performing data filtering could overcome this problem.
Sensor
Preset Area
Figure 4
Tr is OFF during malfunction
and obstacle existence