Data Sheet

UST-10LN Specification
C-42-04211
9/11
Title
Drawing No
Detection area
Output 1
Output 3
Output 2
6-2. Independent configuration
In the independent configuration, areas for Output 1, Output 2 and Output 3 can be configured freely. The field
covered by each output can be completely separate from the other output areas or there can be an overlapping
region between the output areas Figure 5 (a) and (b).
Output 2 represents the detached region configuration
Figure 6 and Table 3 show the relationship between the object position and the output states.
Figure 6: Output areas Table 3:
Relationship between object position and output area
Output 1
Output 2
Output 3
UST Sensor
Figure 5: Independent area configuration
a) without overlapping field
b) with overlapping field
A
C
B
D
E
F
G
H
Object position
Output 1
Output 2
Output 3
A
OFF
ON
ON
B
ON
OFF
ON
C
ON
ON
OFF
D
OFF
OFF
ON
E
OFF
ON
OFF
F
ON
OFF
OFF
G
OFF
OFF
OFF