User Manual
TITLE
DRAWING
NO.
Communication Protocol
Specification
For
SCIP2.0
C-42-03320B
16/25
8.7 [SS-Command]
This command will change the communication bit rate of the sensor when connected with RS232C.
(HOST → SENSOR)
S (53H) S (53H)
Bit Rate
(6 byte)
String Characters LF
Bit Rate:
019200 --- 19.2 Kbps
038400 --- 38.4 Kbps (Some sensor models may not be compatible to this speed)
057600 --- 57.6 Kbps.
115200 --- 115.2 Kbps.
250000 --- 250.0 Kbps
500000 --- 500.0 Kbps
750000 --- 750.0 Kbps.
(SENSOR → HOST)
S S Bit Rate String Characters LF Status Sum LF LF
Status:
00 --- Command received without any Error
01 --- Bit Rate has non-numeric value.
02 --- Invalid Bit Rate
03 --- Sensor is already running at the defied bit rate.
04 --- Not compatible with the sensor model.
Note:
1. See sensor specification for default bit rate during shipment.
2. Bit rate change is implemented only after sensor returns the status 00.
3. When sensor is connected with USB, bit rate change will not have any effect on the communication
speed, but the command will be accepted and effective when connection is changed to RS232C.