TROUBLESHOOTING
ActiveSync Connection Cannot be Established
84 1.3 • 15.01.2007
9.4.3 Checking Registry Entries
If you are unable to establish an ActiveSync connection between
the skeye.pad XSL and the PC via the serial interface, Microsoft
recommends checking that the following Registry entries are
present, and if not, editing the Registry accordingly.
CAUTION!
Registry entries must only be changed by experienced and
authorised users (administrator).
Höft & Wessel as the producer does not accept any liability for
damages (e.g. data loss, security vulnerability and so on)
caused by registry changes.
Procedure for serial connections:
• On your PC call Start ⇒
⇒⇒
⇒ Run ⇒
⇒⇒
⇒ enter Regedit and execute.
• Select HKEY_LOCAL_MACHINE or
HKEY_CURRENT_USESR.
• Open "Software\Microsoft\Windows CE Services".
⇒ Do you see the following entries?
1. [HKEY_LOCAL_MACHINE\Software\Microsoft\
Windows CE Services]
"SerialPort"= <Value> "COM1" (or <Value> COM2)
2. [HKEY_CURRENT_USER\Software\Microsoft\Windows
CE Services]
"SerialBaudRate"=0001c200 (115200) (for 115 kbit/s)
If the entries are not present add them.
Under HKEY_LOCAL_MACHINE click "Windows CE
Services".
Call "Edit ⇒ New ⇒ String Value".
Enter "SerialPort" (no quotation marks)
Double-tap "SerialPort".
The "Modify String" window appears.
Enter COM1 (or the COM port you use).