User Manual

APPENDIX
1.10 18.02.2011 77
10.3.2 Checking the Registry Entries
If it is not possible to establish an ActiveSync connection between skeye.pad POS
and PC, Microsoft recommends checking and, if necessary, adding the following
registry entries on the PC:
[HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows CE Services]
"SerialPort"="COM1" (or COM2)
[HKEY_CURRENT_USER\Software\Microsoft\Windows CE Services]
"SerialBaudRate"=0001c200 (115200) (for 115 kbit/s)
Procedure:
On the PC: Choose Start Run… "Regedit"
Click on HKEY_LOCAL_MACHINE
Open \SOFTWARE\Microsoft\Windows CE Services
Are both entries present?
If not, create them again:
Click on Windows CE Services
Choose the menu item Edit New Character Sequence
Enter ”SerialPort” as a name (without quotation marks)
Double-click "SerialPort", the "Edit character sequence" window opens
Select "Decimal", enter 115200
Select the menu item Edit New DWORD value
Enter "SerialBaudrate" as a name (without quotation marks)
Double-click on "SerialBaudRate", the ”Edit DWORD value" appears
Enter COM1 (or the COM port you are using)
Exit the Registry Editor
Restart the PC so that changes can take effect.