Install Instructions

Steam Vents for Radiators
Model 1A and 1B
Air Valve (non vacuum)
Maximum operating pressure 1
1
2 psig.
Maximum pressure 10 psig.
1A
1/8" NPT
Connection
1B
1/4" NPT
Connection
MAINTENANCE
INSPECT ANNUALLY: This vent allows air to
escape from the radiator as the steam pushes in.
A cold upper part of the radiator may indicate the
vent is plugged with scale or is malfunctioning.
Vapor or slight moisture from the vent is normal.
Steam continuously passing through the vent
indicates a malfunction. Replace the vent as
needed or every 10 years.
Hoffman Specialty
Installation Instructions
HS-100(C)
ITT
8200 N. Austin Ave.
Morton Grove, IL 60053
tel: 847-966-3700
fax: 847-966-9052
www.hoffmanspecialty.com
©2007 ITT Corporation
Printed in U.S.A. 5-07 512500