User Manual

Mode 3: manual trigger or remote control trigger
This is a typical operation mode of GENERAL USE GLOW PLUG DRIVER, it is controlled through receiver or man-
ual. Under manual trigger control mode, it is compatible with trigger operation of mode 1 and mode 2; Under remote
control mode, it will be half power output (stable working mode) when the three-gear switch turns to middle gear, the up
gear is full power output (starting up mode), as soon as the three-gear switch is turned to the up gear for more than 30
seconds, system will enter stable working state automatically, even if the switch is still at its up gear; it will turn off the
driving power output automatically after 5 minutes of stable working mode, so it wont use up the power. If button press-
ing and remote control is operated at the same time, button pressing will get priority for working.
Mode 3
Mode 4: Simple and constant output mode
Please check the following picture: this is the simplest operation way for GENERAL USE GLOW PLUG DRIVER.
Under this mode, short press button will trigger the signal cable B and R before it is powered, so as soon as it is pow-
ered, GENERAL USE GLOW PLUG DRIVER will on full power output, no time limitation, it wont stop working till
the power is turned off or system is overheat. Under this mode, the trigger button only works as indicator light.
Mode 4