User Manual
Profiles
Enables the use of two user profiles to store settings
• Current Profile
o P1 – Profile 1 selected (will be forced to P1 if you select “Yes” for Switch SS & PI).
o P2 – Profile 2 selected.
• Each Profile has all of its own settings, including Receiver type, Motor Layout and ACC
Calibration which will need to be set up and calibrated before you can arm the board when
the profile is selected.
• You will need to power cycle the KK2.1.X if you change to a profile with a different type of
Receiver.
• The SAFE screen will display P1 or P2 in the top left of the display to indicate which profile is
being used.
• Switch SS & PI
o No – Enables you to select either Profile 1 or Profile 2.
o Yes – Forces you to use Profile 1 as the main profile. However, when you switch the
Aux switch, it will use the Stick Scaling and PI settings from Profile 2. If you don’t
want to use Self Level when switching to the Stick Scaling and PI settings from P2
you can set Self Level P Gain to zero in P2 or you can set Self Level to “Stick” in P1.
• To setup the Stick Scaling and PI Gains and Limits in P2, you first have to set Switch SS & PI to
“No” so that you can set the Current Profile to “P2”. It is not necessary to select a motor
layout or ACC calibrate P2 if using this feature. If you leave the PI settings the same in both
profiles but change the Stick Scaling, switching will act like dual rates on your transmitter.
• The SAFE screen will display PI1 or PI2 in the top left of the display to indicate which set of
Stick Scaling and PI settings are being used, depending on the setting of the Aux
channel/switch. You will also see if self level switches On or Off when switching between PI1
and PI2.
• Reset Profile 1
o Factory Reset Profile 1 settings.
• Reset Profile 2
o Factory Reset Profile 1 settings.
• Copy P1 to P2
o Copy all P1 settings to P2
• Copy P2 to P1
o Copy all P2 settings to P1