User Manual

Fail Safe Function (Only for CH2)
Function
Failsafe is a useful feature in which CH2 controls moves to a preset position whenever the control
signal is lost for a period of time.
Setting
1. Turn on the Transmitter switch.
2. Turn on the Receiver switch, the LED will be on.
3. Adjust Transmitter’s CH2 to desired position.
4. Press the “Setting” button on Receiver, the LED will flash, and then stop after 3 seconds, which
means setting finished.
Testing
1. Turn on the Transmitter switch.
2. Turn on the Receiver switch.
3. Turn off the Transmitter switch.
4. Servo on CH2 will turn back to its original Fail Safe setting automatically.
5. Setting is successful if above procedures finished completely.