X-Car 45A ESC manul

D. Instruction:
LiPo Battery Low Voltage Protection / Thermal Protection Setting
ESC stops power while Voltage < 5.6V or Temperature > 90 ; Resume while Voltage 6.5V or
Temperature < 90 .
To check current status:
Switch on ESC and check Motor’s “Beep--”:
• Motor “Beep--” + “SI-LA-SO--” or “SO-LA-SI--”
Status: Record Neutral Point + Protection OFF
• Motor “Beep--Beep--” + “SI-LA-SO--” or “SO-LA-SI--”
Status: Record Neutral Point + Protection ON
To Program:
1) Hold “Programming Switch”.
2) Switch on ESC, release to program according to Motor’s “Beep--”:
• “Beep--”: Both protections are OFF.
• “Beep--Beep--”: Both protections are ON.
• Default Status: OFF.
Mode Setting
To check current status:
Switch on ESC and check Motor’s “Beep--”:
• Motor “Beep--” or “Beep--Beep--” + “SI-LA-SO--” or “SO-LA-SI--” + LED Blink
Status: Practice Mode
• Motor “Beep--” or “Beep--Beep--” + “SI-LA-SO--” or “SO-LA-SI--” + LED ON
Status: Climbing Mode
To Program:
1) Switch on ESC.
2) Hold “Programming Switch” for 2 seconds to change Mode, release to program according to Motor’s “Beep--”:
• “Beep--”: Practice Mode.
• “Beep--Beep--”: Climbing Mode.
• Default Status: Practice Mode.